由技术人员进行筛查眼压测量法。

Screening tonometry by technicians.

作者信息

Krieglstein G K

出版信息

Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1975;194(4 Suppl):221-9. doi: 10.1007/BF00414668.

DOI:10.1007/BF00414668
PMID:236677
Abstract

Comparative measurements of intraocular pressure of 200 eyes were statistical analyzed. Goldmann applanation tonometry was performed by the author and was accepted as a reference system for the measurements made by a technician using the Pneumatonograph, the GlaucoTest screening tonometer, the Halberg tonometer and the Schiotz tonometer. The technician was trained in the use of these instruments for two days; The Pneumatonograph results on seated patients were in good agreement with the Goldmann readings. The GlaucoTest screening tonometer proved to be a good screening instrument for ocular hypertensives and required only a short period of training for the technician. The Halberg tonometer did not give precise readings of intraocular pressure, however, it was more difficult for technicians to use. The Sciotz tonometer appeared to be of limited value in screening tonometry. Some aspects of the influence of body position on i.o; pressure in the different tonometric procedures have been discussed.

摘要

对200只眼睛的眼压进行了对比测量,并进行了统计分析。作者采用Goldmann压平眼压计进行测量,并将其作为技术人员使用气动眼压计、青光眼筛查眼压计、哈尔伯格眼压计和施-氏眼压计测量结果的参考系统。该技术人员接受了为期两天的这些仪器使用培训;气动眼压计对坐位患者的测量结果与Goldmann测量值高度一致。青光眼筛查眼压计被证明是一种用于筛查高眼压症患者的良好仪器,并且技术人员只需经过短时间培训即可使用。然而,哈尔伯格眼压计无法给出精确的眼压读数,而且技术人员使用起来更加困难。施-氏眼压计在眼压筛查中似乎价值有限。本文还讨论了不同眼压测量程序中体位对眼压影响的一些方面。

相似文献

1
Screening tonometry by technicians.由技术人员进行筛查眼压测量法。
Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1975;194(4 Suppl):221-9. doi: 10.1007/BF00414668.
2
Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.比较治疗青光眼患者的眼压回弹式测量、非接触式眼压测量和 Goldmann 压平眼压测量。
Clin Exp Ophthalmol. 2012 May-Jun;40(4):e163-70. doi: 10.1111/j.1442-9071.2011.02670.x. Epub 2011 Oct 20.
3
Goldmann applanation versus hand-applanation and .schiötz indentation tonometry.戈德曼压平眼压计与手持式压平眼压计及施勒茨压陷眼压计的比较。
Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1975;194(1):11-6. doi: 10.1007/BF00408271.
4
Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer.使用气动眼压计和戈德曼眼压计进行眼压测量比较。
Am J Ophthalmol. 1975 Aug;80(2):266-73. doi: 10.1016/0002-9394(75)90144-0.
5
[Clinical comparison of the Tono-Pen tonometer to the Goldmann applanation tonometer].[非接触眼压计与Goldmann压平眼压计的临床比较]
Yan Ke Xue Bao. 2002 Dec;18(4):226-9.
6
Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry.使用“经睑眼压计”TGDc - 01测量眼压并与压平眼压测量法进行比较。
Graefes Arch Clin Exp Ophthalmol. 2005 Jun;243(6):563-9. doi: 10.1007/s00417-004-1037-1. Epub 2004 Dec 22.
7
Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery.用于测量先天性白内障手术后眼压的Goldmann压平眼压计与眼反应分析仪的比较
Eur J Ophthalmol. 2018 Sep;28(5):582-589. doi: 10.1177/1120672118757429. Epub 2018 Mar 15.
8
Influence of body position on the intraocular pressure of normal and glaucomatous eyes.体位对正常眼和青光眼眼眼压的影响。
Ophthalmologica. 1975;171(2):132-45. doi: 10.1159/000307479.
9
[Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes].[使用Proview自动眼压计测量眼压并与Goldmann压平眼压计在健康眼和青光眼眼中的测量结果进行比较]
Klin Monbl Augenheilkd. 2006 Nov;223(11):899-903. doi: 10.1055/s-2006-927094.
10
Portable tonometers: a clinical comparison of applanation and indentation devices.便携式眼压计:压平式与压陷式眼压计的临床比较
J Am Optom Assoc. 1989 Feb;60(2):105-10.

引用本文的文献

1
A glaucoma survey in South India.印度南部的一项青光眼调查。
Doc Ophthalmol. 1984 Jun 15;57(4):357-9. doi: 10.1007/BF00162038.

本文引用的文献

1
SCHIOTZ AND APPLANATION TONOMETRY.施-氏眼压计与压平眼压计测量法
Arch Ophthalmol. 1963 Nov;70:603-9. doi: 10.1001/archopht.1963.00960050605005.
2
On tonometry. 6. Comparative tonometry with the Goldmann applanation tonometer and the Schiötz tonometer in the lying position.
Acta Ophthalmol (Copenh). 1966;44(4):522-38. doi: 10.1111/j.1755-3768.1966.tb08068.x.
3
The visual field defect and ocular pressure level in open angle glaucoma.开角型青光眼的视野缺损与眼压水平
Invest Ophthalmol. 1969 Feb;8(1):105-24.
4
A rapid pneumatic applanation tonometer. Comparative findings and evaluation.
Arch Ophthalmol. 1968 Apr;79(4):389-99. doi: 10.1001/archopht.1968.03850040391006.
5
Halberg tonometer. An evaluation.哈尔伯格眼压计。一项评估。
Arch Ophthalmol. 1971 Oct;86(4):376-84. doi: 10.1001/archopht.1971.01000010378004.
6
Clinical evaluation of the Halberg hand applanation tonometer.哈尔伯格手持式压平眼压计的临床评估
Ann Ophthalmol. 1972 Aug;4(8):634-41.
7
Selective perimetry for glaucomatous defects in ocular hypertension.对高眼压症患者青光眼性缺损进行选择性视野检查。
Arch Ophthalmol. 1972 May;87(5):518-24. doi: 10.1001/archopht.1972.01000020520005.
8
[Border-line tonometry].[临界眼压测量法]
Klin Monbl Augenheilkd. 1972 Jan;160(1):123-5.
9
An evaluation of the GlaucoTest screening tonometer.青光眼检测筛查眼压计的评估
Arch Ophthalmol. 1974 Sep;92(3):195-7. doi: 10.1001/archopht.1974.01010010203002.
10
The influence of position on intraocular pressure.体位对眼压的影响。
Invest Ophthalmol. 1973 Mar;12(3):204-12.