Suppr超能文献

不同脉冲设置的激光照射牙釉质对正畸托槽黏结强度的影响。

Effect of enamel laser irradiation at different pulse settings on shear bond strength of orthodontic brackets.

机构信息

a  Assistant Professor, Department of Orthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey.

出版信息

Angle Orthod. 2013 Nov;83(6):973-80. doi: 10.2319/111412-872.1. Epub 2013 Jun 13.

Abstract

OBJECTIVE

To compare the effect of laser irradiation at two different pulse settings and acid etching on the shear bond strength (SBS) of orthodontic brackets to enamel.

MATERIALS AND METHODS

Thirty-six premolars were allocated to three groups (n  =  12): (1) 37% phosphoric acid etching, (2) erbium-doped yttrium aluminum garnet (Er:YAG) laser etching with medium-short pulse mode (MSP; 100 µs, 120 mj, 10 Hz, 1.2 W), and (3) Er:YAG laser etching with quantum-square pulse mode (QSP; 120 mj, 10 Hz, 1.2 W). Metallic brackets were bonded with Transbond XT. After photopolymerization, the samples were subjected to 5000 thermal cycles and debonded with a universal testing machine, and the SBS values were recorded. Surface morphology was evaluated with profilometric examination, scanning electron microscopy, and atomic force microscopy. The adhesive remnant index (ARI) was evaluated to assess the remaining adhesive.

RESULTS

The results of SBS testing were analyzed by one-way analysis of variance and Tukey honestly significant diffference tests. The mean SBS values of QSP and MSP laser groups were 11.80 ± 2.7 MPa and 10.10 ± 4.5 MPa, respectively, and the QSP group demonstrated significantly higher SBS (P < .01) than that of the acid-etched group (6.6 ± 2.4 MPa). No significant difference was observed between the SBS values of the two laser groups (P < .05). The difference between the ARI scores of the laser groups and the acid-etched group was statistically significant (P < .05).

CONCLUSION

Laser etching at MSP and QSP modes present successful alternatives to acid etching; however, long-term clinical studies are required to verify clinical success.

摘要

目的

比较两种不同脉冲设置的激光照射和酸蚀对正畸托槽与牙釉质的剪切结合强度(SBS)的影响。

材料与方法

将 36 颗前磨牙分为三组(n  =  12):(1)37%磷酸酸蚀,(2)铒石榴石激光(Er:YAG)中短脉冲模式(MSP;100 µs,120 mj,10 Hz,1.2 W)蚀刻,和(3)Er:YAG 激光量子方波脉冲模式(QSP;120 mj,10 Hz,1.2 W)蚀刻。金属托槽用 Transbond XT 粘结。光聚合后,将样品进行 5000 次热循环,用万能试验机进行脱粘,记录 SBS 值。用轮廓仪检查、扫描电子显微镜和原子力显微镜评估表面形态。用黏附残余指数(ARI)评估残留黏附剂。

结果

SBS 测试结果采用单因素方差分析和 Tukey Honestly Significant Difference 检验进行分析。QSP 和 MSP 激光组的平均 SBS 值分别为 11.80 ± 2.7 MPa 和 10.10 ± 4.5 MPa,QSP 组的 SBS 值明显高于酸蚀组(6.6 ± 2.4 MPa)(P <.01)。两组激光组之间的 SBS 值无显著性差异(P <.05)。激光组与酸蚀组的 ARI 评分差异有统计学意义(P <.05)。

结论

MSP 和 QSP 模式的激光蚀刻是酸蚀的有效替代方法;然而,需要进行长期的临床研究来验证临床效果。

相似文献

引用本文的文献

本文引用的文献

2
Surface roughness of the restored enamel after orthodontic treatment.正畸治疗后牙釉质表面粗糙度。
Am J Orthod Dentofacial Orthop. 2010 Mar;137(3):368-74. doi: 10.1016/j.ajodo.2008.02.025.
6
Laser etching of enamel for orthodontic bonding.用于正畸粘结的牙釉质激光蚀刻
Am J Orthod Dentofacial Orthop. 2008 Aug;134(2):193-7. doi: 10.1016/j.ajodo.2006.04.055.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。