Demirok Ahmet, Agca Alper, Ozgurhan Engin Bilge, Bozkurt Ercument, Celik Ugur, Demircan Ali, Guleryuz Nimet Burcu, Cankaya Kadir İlker, Yilmaz Omer Faruk
Department of Ophthalmology, Medeniyet University, Istanbul, Turkey.
Clin Ophthalmol. 2013;7:1041-7. doi: 10.2147/OPTH.S45225. Epub 2013 Jun 7.
To report our initial experience with femtosecond lenticule extraction (FLEX) compared with femtosecond laser-assisted in situ keratomileusis (LASIK).
This was a prospective pilot study carried out at the Refractive Surgery Department of the Beyoglu Eye Training and Research Hospital, Istanbul, Turkey.
Surgery was performed on both eyes of 14 consecutive patients with myopia or myopic astigmatism. Patients underwent FLEX in one eye and femtosecond LASIK (FemtoLASIK) in the other eye. The primary outcome was based on uncorrected distance visual acuity, corrected distance visual acuity, and spherical equivalent of the subjective manifest refraction, at 1 week, 1 month, and 6 months postsurgery. Statistical analyses were performed using PAWS Statistics 18. Unpaired Student's t-test was used to compare the groups.
During the last follow-up visit (6 months postsurgery), the mean spherical was -0.37 ± 0.60 diopters (D) (range -1.00 to 0.50) (P < 0.001) and -0.25 ± 0.41 D (range -0.88 to 0.12 D) (P < 0.001) in the FLEX and FemtoLASIK eyes, respectively. The spherical was within ± 0.50 D of the intended correction in ten (72%) of the FLEX eyes and 12 (86%) of the FemtoLASIK eyes (P > 0.05). No complications occurred during surgery or the postoperative period.
FLEX is a safe, effective, and predictable procedure for surgical correction of myopia. Refractive results were stabilized within the first postoperative week, and visual acuities were stabilized within the first month, comparable to FemtoLASIK.
报告我们在飞秒透镜切除术(FLEX)与飞秒激光原位角膜磨镶术(LASIK)对比中的初步经验。
这是一项在土耳其伊斯坦布尔贝伊奥卢眼科培训与研究医院屈光手术科进行的前瞻性试点研究。
对14例连续的近视或近视散光患者的双眼进行手术。患者一只眼睛接受FLEX手术,另一只眼睛接受飞秒LASIK(飞秒激光原位角膜磨镶术)手术。主要观察指标基于术后1周、1个月和6个月时的未矫正远视力、矫正远视力以及主观显验光的球镜等效度。使用PAWS Statistics 18进行统计分析。采用非配对学生t检验比较两组。
在最后一次随访(术后6个月)时,FLEX组和飞秒激光原位角膜磨镶术组眼睛的平均球镜度数分别为-0.37±0.60屈光度(D)(范围-1.00至0.50)(P<0.001)和-0.25±0.41 D(范围-0.88至0.12 D)(P<0.001)。FLEX组10只眼睛(72%)和飞秒激光原位角膜磨镶术组12只眼睛(86%)的球镜度数在预期矫正值的±0.50 D范围内(P>0.05)。手术期间或术后未发生并发症。
FLEX是一种用于近视手术矫正的安全、有效且可预测的手术方法。屈光结果在术后第一周内稳定,视力在术后第一个月内稳定,与飞秒激光原位角膜磨镶术相当。