Stroh E M, Finger P T
Department of Ophthalmology, North Shore University Hospital-Cornell University Medical College, Manhasset, New York 11030.
Br J Ophthalmol. 1990 Jun;74(6):380-1. doi: 10.1136/bjo.74.6.380.
Orbital emphysema can be produced by trans-conjunctival migration of air from a high pressure airgun. In an industrial accident an 8 mm conjunctival laceration was produced in the superior fornix which acted as a portal of entry for air into the subconjunctival, subcutaneous, and retrobulbar spaces. Computed tomography revealed no evidence of orbital fracture and showed that traumatic orbital emphysema occurred without a broken orbital bone.
眼眶气肿可由高压气枪中的空气经结膜迁移所致。在一次工业事故中,上穹窿处出现了一个8毫米的结膜裂伤,该裂伤成为空气进入结膜下、皮下和球后间隙的入口。计算机断层扫描未发现眼眶骨折的迹象,显示外伤性眼眶气肿是在眼眶骨未骨折的情况下发生的。