The Regional Laboratory of Public Health, Haarlem, The Netherlands,
Eur J Clin Microbiol Infect Dis. 2014 Feb;33(2):279-84. doi: 10.1007/s10096-013-1958-x. Epub 2013 Sep 10.
Generally accepted laboratory methods that have been used for decades do not reliably distinguish between H. influenzae and H. haemolyticus isolates. H. haemolyticus strains are often incorrectly identified as nontypeable Haemophilus influenzae (NTHi). To distinguish H. influenzae from H. haemolyticus we have created a new database on the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) bio-typer 2 and compared the results with routine determination of Haemophilus (growth requirement for X and V factor), and multilocus sequence typing (MLST). In total we have tested 277 isolates, 244 H. influenzae and 33 H. haemolyticus. Using MLST as the gold standard, the agreement of MALDI-TOF MS was 99.6 %. MALDI-TOF MS allows reliable and rapid discrimination between H. influenzae and H. haemolyticus.
通常被接受的实验室方法已经使用了几十年,但不能可靠地区分流感嗜血杆菌和溶血性嗜血杆菌的分离株。溶血性嗜血杆菌菌株通常被错误地鉴定为无定型流感嗜血杆菌(NTHi)。为了将流感嗜血杆菌与溶血性嗜血杆菌区分开来,我们创建了一个新的基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)生物分型仪 2 的数据库,并将结果与常规的嗜血杆菌(X 和 V 因子的生长要求)和多位点序列分型(MLST)进行了比较。我们共测试了 277 株分离株,其中 244 株为流感嗜血杆菌,33 株为溶血性嗜血杆菌。以 MLST 为金标准,MALDI-TOF MS 的一致性为 99.6%。MALDI-TOF MS 可可靠且快速地区分流感嗜血杆菌和溶血性嗜血杆菌。