de Ortueta Diego, von Rüden Dennis, Magnago Thomas, Arba Mosquera Samuel
From Augenzentrum Recklinghausen (De Ortueta, Rüden) Recklinghausen, and Schwind eye-tech-solutions GmbH & Co. KG (Magnago, Arba Mosquera), Kleinostheim, Germany; Recognized Research Group in Optical Diagnostic Techniques (Arba Mosquera), University of Valladolid, Valladolid, Spain.
From Augenzentrum Recklinghausen (De Ortueta, Rüden) Recklinghausen, and Schwind eye-tech-solutions GmbH & Co. KG (Magnago, Arba Mosquera), Kleinostheim, Germany; Recognized Research Group in Optical Diagnostic Techniques (Arba Mosquera), University of Valladolid, Valladolid, Spain.
J Cataract Refract Surg. 2014 Jun;40(6):897-904. doi: 10.1016/j.jcrs.2013.07.050. Epub 2013 Dec 25.
To evaluate the influence of the stromal refractive index and hydration on postoperative outcomes in eyes that had corneal laser refractive surgery using the Amaris laser system.
Augenzentrum Recklinghausen, Recklinghausen, Germany.
Comparative case series.
At the 6-month follow-up, right eyes were retrospectively analyzed. The effect of the stromal refractive index and hydration on refractive outcomes was assessed using univariate linear and multilinear correlations.
Sixty eyes were analyzed. Univariate linear analyses showed that the stromal refractive index and hydration were correlated with the thickness of the preoperative exposed stroma and was statistically different for laser in situ keratomileusis and laser-assisted subepithelial keratectomy treatments. Univariate multilinear analyses showed that the spherical equivalent (SE) was correlated with the attempted SE and stromal refractive index (or hydration). Analyses suggest overcorrections for higher stromal refractive index values and for lower hydration values.
The stromal refractive index and hydration affected postoperative outcomes in a subtle, yet significant manner. An adjustment toward greater attempted correction in highly hydrated corneas and less intended correction in low hydrated corneas might help optimize refractive outcomes.
Mr. Magnago and Dr. Arba-Mosquera are employees of and Dr. Diego de Ortueta is a consultant to Schwind eye-tech-solutions GmbH & Co. KG. Mr. Rüden has no financial or proprietary interest in any material or method mentioned.
评估基质屈光指数和水合作用对使用阿玛里斯激光系统进行角膜激光屈光手术的眼睛术后结果的影响。
德国雷克林豪森奥根zentrum。
比较病例系列。
在6个月的随访中,对右眼进行回顾性分析。使用单变量线性和多线性相关性评估基质屈光指数和水合作用对屈光结果的影响。
分析了60只眼睛。单变量线性分析表明,基质屈光指数和水合作用与术前暴露基质的厚度相关,并且对于准分子原位角膜磨镶术和准分子激光上皮下角膜磨镶术治疗在统计学上存在差异。单变量多线性分析表明,等效球镜度(SE)与预期的SE和基质屈光指数(或水合作用)相关。分析表明,对于较高的基质屈光指数值和较低的水合作用值存在过矫。
基质屈光指数和水合作用以一种微妙但显著的方式影响术后结果。对于高含水量角膜,向更大的预期矫正调整,而对于低含水量角膜,减少预期矫正,可能有助于优化屈光结果。
Magnago先生和Arba-Mosquera博士是Schwind eye-tech-solutions GmbH & Co. KG的员工,Diego de Ortueta博士是该公司的顾问。Rüden先生对文中提及的任何材料或方法均无财务或专利权益。