Suppr超能文献

远视性准分子原位角膜磨镶术:飞秒激光与机械微型角膜刀制作角膜瓣的比较。

Hyperopic laser in situ keratomileusis: comparison of femtosecond laser and mechanical microkeratome flap creation.

作者信息

Antonios Rafic, Arba Mosquera Samuel, Awwad Shady T

机构信息

From the Department of Ophthalmology (Antonios, Awwad), American University of Beirut, Beirut, Lebanon; the Department of Research and Development (Arba Mosquera), Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany; the Recognized Research Group in Optical Diagnostic Techniques (Arba Mosquera), University of Valladolid, Valladolid, and the Department of Ophthalmology and Sciences of Vision (Arba Mosquera), University of Oviedo, Oviedo, Spain.

From the Department of Ophthalmology (Antonios, Awwad), American University of Beirut, Beirut, Lebanon; the Department of Research and Development (Arba Mosquera), Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany; the Recognized Research Group in Optical Diagnostic Techniques (Arba Mosquera), University of Valladolid, Valladolid, and the Department of Ophthalmology and Sciences of Vision (Arba Mosquera), University of Oviedo, Oviedo, Spain.

出版信息

J Cataract Refract Surg. 2015 Aug;41(8):1602-9. doi: 10.1016/j.jcrs.2014.11.049.

Abstract

PURPOSE

To evaluate and compare the refractive predictability and stability of laser in situ keratomileusis (LASIK) flap creation performed with a femtosecond laser and with a mechanical microkeratome to correct mild to moderate hyperopia.

SETTING

American University of Beirut Medical Center, Beirut, Lebanon.

DESIGN

Retrospective case series.

METHODS

Patients who had hyperopic LASIK treatment using the Amaris excimer laser were included. Eyes in which the LDV femtosecond laser was used for flap creation were compared with eyes in which the Moria M2 microkeratome was used.

RESULTS

The microkeratome group comprised 53 eyes and the femtosecond laser group, 72 eyes. Baseline characteristics were similar between groups (P > .05). The mean spherical equivalent (SE) deviation from target 1 week postoperatively was -0.08 diopter (D) ± 0.58 (SD) in the femtosecond laser group and -0.06 ± 0.87 D in the microkeratome group (P = .92). Thereafter, the mean SE deviation from target increased gradually and by 6 months postoperatively was +0.30 ± 0.50 D and +0.70 ± 0.71 D, respectively (P = .001). The correlation between the achieved and the attempted SE refraction was better in the femtosecond laser group (R(2) = 0.806) than the microkeratome group (R(2) = 0.671).

CONCLUSIONS

Using the same nomogram, the short-term refractive outcomes of hyperopic LASIK with flap creation performed with the femtosecond laser were comparable to those for the microkeratome; however, the femtosecond group showed significantly better stability over the 6-month follow-up and better predictability, as reflected by a lower standard deviation and stronger Pearson correlation.

FINANCIAL DISCLOSURE

Dr. Arba Mosquera is an employee of Schwind eye-tech-solutions GmbH and Co. KG. No other author has a financial or proprietary interest in any material or method mentioned.

摘要

目的

评估和比较使用飞秒激光和机械微型角膜刀制作角膜瓣的准分子原位角膜磨镶术(LASIK)矫正轻至中度远视的屈光预测性和稳定性。

设置

黎巴嫩贝鲁特美国大学医疗中心。

设计

回顾性病例系列。

方法

纳入使用阿玛里斯准分子激光进行远视LASIK治疗的患者。将使用LDV飞秒激光制作角膜瓣的眼与使用Moria M2微型角膜刀的眼进行比较。

结果

微型角膜刀组有53只眼,飞秒激光组有72只眼。两组的基线特征相似(P>.05)。飞秒激光组术后1周与目标值的平均球镜等效度(SE)偏差为-0.08屈光度(D)±0.58(标准差),微型角膜刀组为-0.06±0.87 D(P =.92)。此后,与目标值的平均SE偏差逐渐增加,术后6个月分别为+0.30±0.50 D和+0.70±0.71 D(P =.001)。飞秒激光组实现的与尝试的SE屈光度之间的相关性(R² = 0.806)优于微型角膜刀组(R² = 0.671)。

结论

使用相同的列线图,飞秒激光制作角膜瓣的远视LASIK短期屈光结果与微型角膜刀相当;然而,飞秒激光组在6个月的随访中显示出明显更好的稳定性和更好的预测性,表现为标准差更低和皮尔逊相关性更强。

财务披露

阿尔瓦·莫斯克拉博士是Schwind eye-tech-solutions GmbH and Co. KG的员工。其他作者对文中提及的任何材料或方法均无财务或专利权益。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验