Suppr超能文献

评估HER2阳性乳腺癌小鼠模型中扩散加权磁共振成像研究的可重复性。

Assessing reproducibility of diffusion-weighted magnetic resonance imaging studies in a murine model of HER2+ breast cancer.

作者信息

Whisenant Jennifer G, Ayers Gregory D, Loveless Mary E, Barnes Stephanie L, Colvin Daniel C, Yankeelov Thomas E

机构信息

Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232-2675; Department of Program in Chemical and Physical Biology, Vanderbilt University, Nashville, Tennessee 37232-2675.

Department of Biostatistics, Vanderbilt University, Nashville, Tennessee 37232-2675.

出版信息

Magn Reson Imaging. 2014 Apr;32(3):245-9. doi: 10.1016/j.mri.2013.10.013. Epub 2013 Dec 14.

Abstract

BACKGROUND AND PURPOSE

The use of diffusion-weighted magnetic resonance imaging (DW-MRI) as a surrogate biomarker of response in preclinical studies is increasing. However, before a biomarker can be reliably employed to assess treatment response, the reproducibility of the technique must be established. There is a paucity of literature that quantifies the reproducibility of DW-MRI in preclinical studies; thus, the purpose of this study was to investigate DW-MRI reproducibility in a murine model of HER2+ breast cancer.

MATERIALS AND METHODS

Test-Retest DW-MRI scans separated by approximately six hours were acquired from eleven athymic female mice with HER2+ xenografts using a pulsed gradient spin echo diffusion-weighted sequence with three b values [150, 500, and 800s/mm(2)]. Reproducibility was assessed for the mean apparent diffusion coefficient (ADC) from tumor and muscle tissue regions.

RESULTS

The threshold to reflect a change in tumor physiology in a cohort of mice is defined by the 95% confidence interval (CI), which was±0.0972×10(-3)mm(2)/s (±11.8%) for mean tumor ADC. The repeatability coefficient defines this threshold for an individual mouse, which was±0.273×10(-3)mm(2)/s. The 95% CI and repeatability coefficient for mean ADC of muscle tissue were±0.0949×10(-3)mm(2)/s (±8.30%) and±0.266×10(-3)mm(2)/s, respectively.

CONCLUSIONS

Mean ADC of tumors is reproducible and appropriate for detecting treatment-induced changes on both an individual and mouse cohort basis.

摘要

背景与目的

在临床前研究中,扩散加权磁共振成像(DW-MRI)作为反应替代生物标志物的应用日益增加。然而,在生物标志物能够可靠地用于评估治疗反应之前,必须确定该技术的可重复性。目前缺乏在临床前研究中量化DW-MRI可重复性的文献;因此,本研究的目的是在HER2+乳腺癌小鼠模型中研究DW-MRI的可重复性。

材料与方法

使用具有三个b值[150、500和800s/mm(2)]的脉冲梯度自旋回波扩散加权序列,对11只患有HER2+异种移植瘤的无胸腺雌性小鼠进行间隔约6小时的重测DW-MRI扫描。评估肿瘤和肌肉组织区域的平均表观扩散系数(ADC)的可重复性。

结果

反映一组小鼠肿瘤生理学变化的阈值由95%置信区间(CI)定义,平均肿瘤ADC的95%CI为±0.0972×10(-3)mm(2)/s(±11.8%)。重复性系数定义了单个小鼠的该阈值,为±0.273×10(-3)mm(2)/s。肌肉组织平均ADC的95%CI和重复性系数分别为±0.0949×10(-3)mm(2)/s(±8.30%)和±0.266×10(-3)mm(2)/s。

结论

肿瘤的平均ADC具有可重复性,适用于在个体和小鼠群体基础上检测治疗引起的变化。

相似文献

5
Repeatability of diffusion-weighted imaging in rectal cancer.直肠癌扩散加权成像的可重复性
J Magn Reson Imaging. 2014 Jul;40(1):146-50. doi: 10.1002/jmri.24337. Epub 2013 Oct 11.

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验