Grazhdani Hektor, Cantisani Vito, Lodise Pietro, Di Rocco Giorgio, Proietto Maria Cristina, Fioravanti Eloisa, Rubini Antonello, Redler Adriano
Department of Radiology, "Sapienza" University of Rome, Rome, Italy ; Department of Radiological, Oncological and Anatomopathological Sciences, "Sapienza" University of Rome, Policlinico Umberto I, Viale Regina Elena, 324, 00161 Rome, Italy.
Department of Radiology, "Sapienza" University of Rome, Rome, Italy.
J Ultrasound. 2014 Jan 9;17(1):13-20. doi: 10.1007/s40477-013-0062-5. eCollection 2014 Mar.
The aim of this study is to assess the diagnostic efficacy and interobserver agreement of acoustic radiation force impulse (ARFI) elasticity imaging in differentiating thyroid nodules.
In our study, 74 consecutive patients (52 females, 22 males; age range 27-77 years, mean: 41 years) with 82 thyroid nodules (60 benign nodules, and 22 malignant) were examined by two radiologists with different experience. Patients underwent either cytology using fine needle aspiration cytology or thyroid surgery. The diagnostic performance of the two operators at ARFI with sensitivity, specificity, positive predictive and negative predictive value, and ROC curves was estimated. Inter-reader variability between the two operators was defined using Cohen's k.
According to receiver operating characteristics ROC curves (AUROC = 0.86 for observer 1; 0.81 for observer 2) sensitivity, specificity, PPV and NPV of reader 1 and 2 were respectively: 90, 75, 90.91 and 96.55 %; (cut-off value of shear wave: 2.455 m/s); 90, 72, 90 and 96.90 % (cut-off value shear wave: 2.365 m/s). Concordance between the two operators was good (k = 0.755).
This work is a feasibility study evaluating ARFI imaging. Its results suggest that ARFI imaging is a reproducible method which can be utilized with good diagnostic performance in the thyroid for discriminating benign and malignant nodules using the cut-off value of 2.455 m/s. However, larger studies are needed to validate this method.
本研究旨在评估声辐射力脉冲(ARFI)弹性成像在鉴别甲状腺结节中的诊断效能及观察者间的一致性。
在我们的研究中,74例连续患者(52例女性,22例男性;年龄范围27 - 77岁,平均41岁),共82个甲状腺结节(60个良性结节和22个恶性结节)由两位经验不同的放射科医生进行检查。患者接受了细针穿刺细胞学检查或甲状腺手术。评估了两位操作者在ARFI检查中的诊断性能,包括敏感性、特异性、阳性预测值和阴性预测值,以及ROC曲线。使用Cohen's k定义两位操作者之间的阅片者变异性。
根据受试者工作特征曲线(观察者1的AUROC = 0.86;观察者2的AUROC = 0.81),观察者1和2的敏感性、特异性、PPV和NPV分别为:90%、75%、90.91%和96.55%(剪切波临界值:2.455 m/s);90%、72%、90%和96.90%(剪切波临界值:2.365 m/s)。两位操作者之间的一致性良好(k = 0.755)。
本研究是一项评估ARFI成像的可行性研究。其结果表明,ARFI成像是一种可重复的方法,在甲状腺中使用2.455 m/s的临界值鉴别良性和恶性结节时具有良好的诊断性能。然而,需要更大规模的研究来验证该方法。