Healing of implants installed in over- or under-prepared sites--an experimental study in dogs.

作者信息

Rea Massimiliano, Lang Niklaus P, Ricci Sara, Mintrone Francesco, González González Gladys, Botticelli Daniele

机构信息

Faculty of Dentistry, University of Medical Science, La Habana, Cuba.

The University of Hong Kong, Prince Philip Dental Hospital, Hong Kong, China.

出版信息

Clin Oral Implants Res. 2015 Apr;26(4):442-446. doi: 10.1111/clr.12390. Epub 2014 Mar 31.

Abstract

OBJECTIVE

To study bone healing at implants installed with different insertion torques.

MATERIAL AND METHODS

In six Labrador dogs, all mandibular premolars and first molars were extracted. After 4 months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. In the right side of the mandible, the distal sites were prepared conventionally, while the mesial sites were over-prepared by 0.2 mm. As a consequence, a final insertion torque of ~30 Ncm at the distal and a minimal insertion torque close to 0 Ncm at the mesial sites were obtained. In the left sides of the mandible, however, the recipient sites were underprepared by 0.3 mm resulting in an insertion torque of ≥ 70 Ncm at both implants. Cover screws were applied, and flaps sutured to fully submerge the experimental sites. After 4 months, the animals were sacrificed and ground sections obtained for histological evaluation.

RESULTS

The mineralized bone-to-implant contact was in the range of 55.2-62.1%, displaying the highest value at implants with ~30 Ncm insertion torque and the lowest value at the implant sites with close to 0 Ncm insertion torque. No statistically significant differences were revealed. Bone density was in the range of 43.4-54.9%, yielding the highest value at implants with ≥ 70 Ncm insertion torque and the lowest at the implant sites with close to 0 Ncm insertion torque. The difference between the sites of ~30 Ncm and the corresponding ≥ 70 Ncm insertion torque reached statistical significance.

CONCLUSIONS

Similar amounts of osseointegration were obtained irrespective of the insertion torque applied. Moreover, implants installed in sites with close to 0 Ncm insertion torque may properly osseointegrate as well.

摘要

目的

研究不同植入扭矩下种植体周围的骨愈合情况。

材料与方法

选取6只拉布拉多犬,拔除所有下颌前磨牙和第一磨牙。愈合4个月后,掀起皮瓣,在下颌骨两侧各制备两个种植位点。在下颌骨右侧,远中端位点按常规方法制备,而近中端位点过度制备0.2mm。结果,远中端获得约30Ncm的最终植入扭矩,近中端获得接近0Ncm的最小植入扭矩。然而,在下颌骨左侧,种植位点制备不足0.3mm,导致两个种植体的植入扭矩均≥70Ncm。拧上覆盖螺丝,缝合皮瓣以完全覆盖实验位点。4个月后,处死动物并获取磨片进行组织学评估。

结果

矿化骨与种植体的接触率在55.2%-62.1%之间,在植入扭矩约为30Ncm的种植体处最高,在植入扭矩接近0Ncm的种植位点处最低。未发现统计学上的显著差异。骨密度在43.4%-54.9%之间,在植入扭矩≥70Ncm的种植体处最高,在植入扭矩接近0Ncm的种植位点处最低。植入扭矩约为30Ncm的位点与相应的≥70Ncm植入扭矩位点之间的差异具有统计学意义。

结论

无论应用何种植入扭矩,均可获得相似程度的骨结合。此外,植入扭矩接近0Ncm的种植体也可能实现良好的骨结合。