Suppr超能文献

皮质骨厚度会影响微型螺钉的初期稳定性吗?:一项系统评价与荟萃分析。

Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

作者信息

Marquezan Mariana, Mattos Cláudia Trindade, Sant'Anna Eduardo Franzotti, de Souza Margareth Maria Gomes, Maia Lucianne Cople

机构信息

a  Private practice, Santa Maria, RS, Brazil.

出版信息

Angle Orthod. 2014 Nov;84(6):1093-103. doi: 10.2319/093013-716.1. Epub 2014 Apr 2.

Abstract

OBJECTIVE

To investigate whether there is evidence to support the association between cortical thickness (CtTh) and the primary stability of mini-implants (MI).

MATERIALS AND METHODS

A search was performed including articles published until September 2013. The inclusion criteria comprised observational clinical studies conducted in patients who received monocortical MI for orthodontic anchorage and in vivo or ex vivo experimental studies performed to evaluate the primary stability of MI, studies that evaluated the association between CtTh and MI primary stability, CtTh measurement performed numerically, and MI primary stability evaluated by implant stability quotient value, Periotest value , pull-out strength, or insertion torque. Studies conducted exclusively in artificial bone or finite elements were excluded.

RESULTS

Abstract and title reading identified 15 possible articles to be included. After reading the complete text, three were excluded. One article was found by hand searching and another excluded for an overlapping sample. Finally, 12 articles were selected. A positive correlation was found between primary stability and CtTh when studies that evaluated primary stability through PS were grouped (r  =  .409) and when studies that evaluated stability in humans were grouped (r  =  .338).

CONCLUSIONS

There is a positive association between MI primary stability and CtTh of the receptor site. However, there is still a lack of well-designed clinical trials.

摘要

目的

探讨是否有证据支持皮质厚度(CtTh)与微型种植体(MI)的初期稳定性之间存在关联。

材料与方法

进行检索,纳入截至2013年9月发表的文章。纳入标准包括对接受单皮质MI用于正畸支抗的患者进行的观察性临床研究,以及为评估MI的初期稳定性而进行的体内或体外实验研究,评估CtTh与MI初期稳定性之间关联的研究,以数值方式进行的CtTh测量,以及通过种植体稳定性商值、牙周探测值、拔出力或植入扭矩评估的MI初期稳定性。仅在人工骨或有限元中进行的研究被排除。

结果

通过摘要和标题阅读确定了15篇可能纳入的文章。阅读全文后,排除了3篇。通过手工检索发现1篇文章,因样本重叠又排除1篇。最终,选择了12篇文章。当将通过种植体稳定性商值(PS)评估初期稳定性的研究分组时(r = 0.409),以及将评估人类稳定性的研究分组时(r = 0.338),发现初期稳定性与CtTh之间存在正相关。

结论

MI的初期稳定性与受体部位的CtTh之间存在正相关。然而,仍然缺乏设计良好的临床试验。

相似文献

1
Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.
Angle Orthod. 2014 Nov;84(6):1093-103. doi: 10.2319/093013-716.1. Epub 2014 Apr 2.
2
Insertion torque and success of orthodontic mini-implants: a systematic review.
Am J Orthod Dentofacial Orthop. 2012 Nov;142(5):596-614.e5. doi: 10.1016/j.ajodo.2012.06.013.
4
In vitro physical properties and clinical stability of reused orthodontic miniscrews: A systematic review and meta-analysis.
J World Fed Orthod. 2025 Apr;14(2):97-110. doi: 10.1016/j.ejwf.2024.09.005. Epub 2024 Oct 29.
5
Does bone mineral density influence the primary stability of dental implants? A systematic review.
Clin Oral Implants Res. 2012 Jul;23(7):767-74. doi: 10.1111/j.1600-0501.2011.02228.x. Epub 2011 Jun 2.
6
Orthodontic treatment for prominent lower front teeth (Class III malocclusion) in children.
Cochrane Database Syst Rev. 2024 Apr 10;4(4):CD003451. doi: 10.1002/14651858.CD003451.pub3.
7
Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods.
Cochrane Database Syst Rev. 2014 Aug 19;2014(8):CD005098. doi: 10.1002/14651858.CD005098.pub3.
8
Survival and failure rates of orthodontic temporary anchorage devices: a systematic review.
Clin Oral Implants Res. 2009 Dec;20(12):1351-9. doi: 10.1111/j.1600-0501.2009.01754.x. Epub 2009 Sep 30.

引用本文的文献

2
Evaluation of Two Mini-implant Lengths in the Infrazygomatic Crest Region: A Randomized Clinical Trial.
Eur J Dent. 2025 May;19(2):399-408. doi: 10.1055/s-0044-1789015. Epub 2024 Nov 7.
5
Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: an in vitro study.
Dental Press J Orthod. 2024 May 20;29(2):e2423282. doi: 10.1590/2177-6709.29.2.e2423282.oar. eCollection 2024.
7
Influence of the third molar presence on the thickness and height of the buccal cortical bone of the mandibular first and second molars.
J Clin Exp Dent. 2023 Jun 1;15(6):e478-e487. doi: 10.4317/jced.60428. eCollection 2023 Jun.
9
Failure rates and factors associated with infrazygomatic crestal orthodontic implants - A prospective study.
J Oral Biol Craniofac Res. 2023 Mar-Apr;13(2):283-289. doi: 10.1016/j.jobcr.2023.02.010. Epub 2023 Feb 25.

本文引用的文献

1
Cortical bone strains around straight and angulated immediate orthodontic microimplants: a pilot study.
Implant Dent. 2013 Apr;22(2):133-7. doi: 10.1097/ID.0b013e31827b96c2.
2
Insertion torque and success of orthodontic mini-implants: a systematic review.
Am J Orthod Dentofacial Orthop. 2012 Nov;142(5):596-614.e5. doi: 10.1016/j.ajodo.2012.06.013.
3
Measurement of mini-implant stability using resonance frequency analysis.
Angle Orthod. 2013 Mar;83(2):230-8. doi: 10.2319/043012-354.1. Epub 2012 Aug 29.
4
Miniscrew design and bone characteristics: an experimental study of primary stability.
Am J Orthod Dentofacial Orthop. 2012 Aug;142(2):228-34. doi: 10.1016/j.ajodo.2012.03.029.
5
Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
Am J Orthod Dentofacial Orthop. 2012 Feb;141(2):187-95. doi: 10.1016/j.ajodo.2011.07.020.
6
Effect of miniscrew placement torque on resistance to miniscrew movement under load.
Am J Orthod Dentofacial Orthop. 2011 Sep;140(3):e93-8. doi: 10.1016/j.ajodo.2011.04.017.
7
Does bone mineral density influence the primary stability of dental implants? A systematic review.
Clin Oral Implants Res. 2012 Jul;23(7):767-74. doi: 10.1111/j.1600-0501.2011.02228.x. Epub 2011 Jun 2.
8
Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage.
Int J Oral Maxillofac Surg. 2011 Jul;40(7):697-703. doi: 10.1016/j.ijom.2010.08.008. Epub 2011 Apr 1.
9
The role of primary stability for successful immediate loading of dental implants. A literature review.
J Dent. 2010 Aug;38(8):612-20. doi: 10.1016/j.jdent.2010.05.013. Epub 2010 Jun 11.
10
Accuracy of mechanical torque-limiting gauges for mini-screw placement.
Clin Oral Implants Res. 2010 Aug;21(8):781-8. doi: 10.1111/j.1600-0501.2010.01927.x. Epub 2010 May 3.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验