Suppr超能文献

使用一种具有功能和可降解特性的增强装置,对大体积和巨大肩袖撕裂进行长期成功的关节镜修复。

Long-term successful arthroscopic repair of large and massive rotator cuff tears with a functional and degradable reinforcement device.

机构信息

Alta Orthopedics, Santa Barbara, CA, USA.

出版信息

J Shoulder Elbow Surg. 2014 Oct;23(10):1508-13. doi: 10.1016/j.jse.2014.01.010. Epub 2014 Apr 13.

Abstract

BACKGROUND

Rotator cuff repair is a procedure with varying outcomes, and there has been subsequent interest in devices that reinforce the repair and enhance structural and functional outcomes. The objective of this study was to determine these outcomes for arthroscopic repair of large and massive rotator cuff tears augmented with a synthetic absorbable mesh designed specifically for reinforcement of tendon repair by imaging and clinical assessments.

MATERIALS AND METHODS

Consecutive arthroscopic repairs were performed on 18 patients with large to massive rotator cuff tears by use of a poly-l-lactic acid synthetic patch as a reinforcement device and fixation with 4 sutures. Patients were assessed preoperatively and at 6 months, 12 months, and a mean of 42 months after surgery by the American Shoulder and Elbow Surgeons (ASES) shoulder score to evaluate clinical performance and at 12 months by ultrasound to assess structural repair.

RESULTS

Ultrasound showed that 15 of 18 patients had intact rotator cuff repair at 12 months; at 42 months, an additional patient had a failed repair. Patients showed improvement in the ASES shoulder score from 25 preoperatively to 71 at 12 months and 70 at 42 months after surgery. Patients with intact rotator cuff (n = 14) at 42 months had an ASES shoulder score of 82.

DISCUSSION

The poly-l-lactic acid bioabsorbable patch designed specifically to reinforce the surgical repair of tendons supported successful repair of large to massive rotator cuff tears in 83% of patients at 12 months after surgery and 78% of patients at 42 months after surgery, with substantial functional improvement.

摘要

背景

肩袖修复术的结果存在差异,此后人们对可增强修复效果、改善结构和功能结果的器械产生了兴趣。本研究旨在通过影像学和临床评估,确定特定于增强肌腱修复的合成可吸收补片增强的关节镜修复大型和巨大肩袖撕裂的这些结果。

材料和方法

连续对 18 例大型至巨大肩袖撕裂患者进行关节镜修复,使用聚-L-乳酸合成补片作为增强装置,并用 4 根缝线固定。患者在术前和术后 6 个月、12 个月和平均 42 个月时使用美国肩肘外科医生协会(ASES)肩部评分进行评估,以评估临床表现,并在术后 12 个月时通过超声评估结构修复。

结果

超声显示,18 例患者中有 15 例在 12 个月时肩袖修复完整;42 个月时,又有 1 例修复失败。患者的 ASES 肩部评分从术前的 25 分提高到 12 个月时的 71 分和 42 个月时的 70 分。在 42 个月时肩袖完整的患者(n=14)的 ASES 肩部评分为 82。

讨论

专门设计用于增强肌腱手术修复的聚-L-乳酸可吸收补片在术后 12 个月时成功修复了 83%的大型至巨大肩袖撕裂患者,在术后 42 个月时修复成功率为 78%,患者功能显著改善。