Suppr超能文献

三种活动监测仪在慢性阻塞性肺疾病患者中的准确性:与视频记录的比较

Accuracy of three activity monitors in patients with chronic obstructive pulmonary disease: a comparison with video recordings.

作者信息

Andersson Mikael, Janson Christer, Emtner Margareta

机构信息

1Department of Neuroscience, Physiotherapy, Uppsala University , Uppsala , Sweden.

出版信息

COPD. 2014 Sep;11(5):560-7. doi: 10.3109/15412555.2014.898033. Epub 2014 Apr 15.

Abstract

Low physical activity and sedentary behaviour characterise the lives of patients with chronic obstructive pulmonary disease (COPD). Using activity monitors, assessment of both aspects are possible, but many outcomes are not well validated. The aim of this study was to assess the accuracy and equivalency of three activity monitors regarding steps, body position and their ability to differentiate between periods of physical activity and inactivity. Fifteen patients with COPD (8 females; median (interquartile range, IQR) age, 64 (59-69) years; forced expiratory volume in 1 second, 37 (28-48)% predicted; 6-minute walk distance, 444 (410-519) m) were enrolled. The DynaPort ADL-monitor, the DynaPort MiniMod monitor and the SenseWear Armband Pro 3 monitor were assessed. Subjects performed a structured protocol alternating physical activity and inactivity while simultaneously wearing all three monitors and being video recorded. The mean difference (limits of agreement) in step count from monitors compared to manual step count was -69 (-443 to 305) for the ADL-monitor, -19 (-141 to 103) for the MiniMod and -479 (-855 to -103) for the SenseWear Armband. Compared to the video, the sitting time was 97 (94-100)% when measured by the ADL-monitor and 121 (110-139)% by the MiniMod. Standing time was 114 (107-122)% when measured by the ADL-monitor and 68 (47-106)% by the MiniMod. Activity monitors are not equivalent in their abilities to detect steps or body positions. The choice of monitor should be based on the particular outcome of interest.

摘要

身体活动不足和久坐行为是慢性阻塞性肺疾病(COPD)患者生活的特征。使用活动监测器可以对这两个方面进行评估,但许多结果尚未得到充分验证。本研究的目的是评估三种活动监测器在步数、身体姿势方面的准确性和等效性,以及它们区分身体活动和不活动时段的能力。招募了15名COPD患者(8名女性;年龄中位数(四分位间距,IQR)为64(59 - 69)岁;第1秒用力呼气量为预测值的37(28 - 48)%;6分钟步行距离为444(410 - 519)米)。对DynaPort ADL监测器、DynaPort MiniMod监测器和SenseWear Armband Pro 3监测器进行了评估。受试者执行了一个交替进行身体活动和不活动的结构化方案,同时佩戴所有三种监测器并进行视频记录。与手动计数步数相比,ADL监测器的步数平均差异(一致性界限)为 -69(-443至305),MiniMod为 -19(-141至103),SenseWear Armband为 -479(-855至 -103)。与视频相比,ADL监测器测量的坐姿时间为97(94 - 100)%,MiniMod为121(110 - 139)%。ADL监测器测量的站立时间为114(107 - 122)%,MiniMod为68(47 - 106)%。活动监测器在检测步数或身体姿势的能力方面并不等效。监测器的选择应基于感兴趣的特定结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验