Reliability analysis of two methods for measuring active enamel demineralization: An in vitro study.

作者信息

Nassur Camila, Pomarico Luciana, Maia Lucianne Cople

机构信息

Department of Pediatric Dentistry and Orthodontics, Dental School, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.

Department of Specific Formation, Dental School, Federal Fluminense University, Nova Friburgo, Brazil.

出版信息

Eur J Dent. 2013 Apr;7(2):159-164. doi: 10.4103/1305-7456.110157.

Abstract

OBJECTIVE

The aim was to evaluate the intra- and inter-examiner reliability of two methods, namely, digital caliper [DC] and computerized image analysis software (Image Tool [IT] version 4.1) for measuring the area of an active enamel demineralization lesion. The effect on that measurement of a window that delimits the lesion was also assessed.

MATERIALS AND METHODS

Thirty-eight circular artificial enamel demineralization lesions (r = 2 mm) were produced on bovine teeth in vitro, which were then measured three times by three examiners, with and without the presence of a window delimiting the area to be measured. The data were analyzed by the intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and by the Altman and Bland analysis.

RESULTS

The intra-examiner correlation using the IT method showed excellent reproducibility (mean ICC values 0.922-0.970 with the delimiting window and 0.915-0.990 without the window). However, the intra-examiner correlation using the DC method showed comparatively less reproducibility in the measurements (mean ICC values 0.458-0.648 with the delimiting window and 0.378-0.665 without the window). The inter-examiner correlations showed very good reproducibility of the measurements regardless of the presence or absence of the window for both the DC method (0.811-0.846) and IT method (0.953-0.994). However, the latter method showed less variability within the measurements.

CONCLUSION

However, statistically no significant difference was found between both methodologies. Nevertheless, computerized image analysis with the Image Tool software demonstrated higher intra- and inter-examiner reliability than the digital caliper method, in estimating the area of the enamel demineralization lesion, regardless of the delimiting window.