角膜屈光手术后采用新型Scheimpflug技术检查眼生物力学。

Examination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgery.

作者信息

Hassan Ziad, Modis Laszlo, Szalai Eszter, Berta Andras, Nemeth Gabor

机构信息

Orbi-Dent Health and Laser Center, Debrecen, Hungary.

Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.

出版信息

Cont Lens Anterior Eye. 2014 Oct;37(5):337-41. doi: 10.1016/j.clae.2014.05.001. Epub 2014 Jun 2.

Abstract

PURPOSE

To analyze the early results of a new device measuring ocular biomechanics after corneal refractive surgery.

PATIENTS AND METHODS

Thirty nine refractive surgery patients were enrolled in the study (age: 32.6±9.9 years). Laser in situ keratomileusis (LASIK) was performed on 52 eyes of 26 patients and photorefractive keratectomy (PRK) was done on 26 eyes of 13 patients. Ten device-specific biomechanical parameters, intraocular pressure (IOP) and pachymetry were measured preoperatively and at day 1, week 1 and month 1 after the surgeries with a new technology based on Scheimpflug imaging (CorVis ST, Oculus).

RESULTS

In case of LASIK, the day after the procedure, radius values showed significant differences compared to preoperative data. One month after surgery, radius values, velocity of the second applanation and pachymetry showed significant differences compared to preoperative data. In case of PRK, the day after the procedure, significant differences in IOP, maximum amplitude at the apex, A1 time, A2 velocity and highest concavity time were measured. After 1 month of PRK, there were no differences in the parameters compared to preoperative data except pachymetry.

CONCLUSIONS

We observed that some specific biomechanical parameters changed measured with CorVis ST after LASIK and PRK, in the early postoperative time. However, most of these parameters remain unchanged after one month of LASIK and PRK compared to preoperative data.

摘要

目的

分析一种用于测量角膜屈光手术后眼生物力学的新设备的早期结果。

患者与方法

39名屈光手术患者纳入本研究(年龄:32.6±9.9岁)。26例患者的52只眼行准分子原位角膜磨镶术(LASIK),13例患者的26只眼行准分子激光角膜切削术(PRK)。采用基于Scheimpflug成像的新技术(CorVis ST,Oculus)在术前、术后第1天、第1周和第1个月测量10项特定于该设备的生物力学参数、眼压(IOP)和角膜厚度。

结果

LASIK术后第1天,曲率半径值与术前数据相比有显著差异。术后1个月,曲率半径值、第二次压平速度和角膜厚度与术前数据相比有显著差异。PRK术后第1天,测量到眼压、顶点最大振幅、A1时间、A2速度和最高凹陷时间有显著差异。PRK术后1个月,除角膜厚度外,与术前数据相比各参数无差异。

结论

我们观察到,LASIK和PRK术后早期,用CorVis ST测量的一些特定生物力学参数发生了变化。然而,与术前数据相比,LASIK和PRK术后1个月大多数这些参数保持不变。