Park Jea-Beom, Kim Eun-Young, Paek Janghyun, Kook Yoon-Ah, Jeong Do-Min, Cho Il-Sik, Nelson Gerald
Department of Orthodontics, The Catholic University of Korea, Seoul, Republic of Korea.
Department of Dentistry, National Medical Center of Korea, 245 Euljiro, Junggu, Seoul 100-799, Republic of Korea.
Int J Dent. 2014;2014:429359. doi: 10.1155/2014/429359. Epub 2014 May 11.
Objective. This study aimed to evaluate effects of type 1 diabetes mellitus and mini-implant placement method on the primary stability of mini-implants by comparing mechanical stability and microstructural/histological differences. Methods. After 4 weeks of diabetic induction, 48 mini-implants (24 self-tapping and 24 self-drilling implants) were placed on the tibia of 6 diabetic and 6 normal rabbits. After 4 weeks, the rabbits were sacrificed. Insertion torque, removal torque, insertion energy, and removal energy were measured with a surgical engine on 8 rabbits. Remaining 4 rabbits were analyzed by microcomputed tomography (micro-CT) and bone histomorphometry. Results. Total insertion energy was higher in self-drilling groups than self-tapping groups in both control and diabetic groups. Diabetic groups had more trabecular separation in bone marrow than the control groups in both SD and ST groups. Micro-CT analysis showed deterioration of bone quality in tibia especially in bone marrow of diabetic rabbits. However, there was no statistically significant correlation between self-drilling and self-tapping group for the remaining measurements in both control and diabetic groups. Conclusions. Type 1 diabetes mellitus and placement method of mini-implant did not affect primary stability of mini-implants.
目的。本研究旨在通过比较机械稳定性以及微观结构/组织学差异,评估1型糖尿病和微型种植体植入方法对微型种植体初期稳定性的影响。方法。在诱导糖尿病4周后,将48枚微型种植体(24枚自攻型和24枚自钻型种植体)植入6只糖尿病兔和6只正常兔的胫骨。4周后,处死兔子。用外科动力装置对8只兔子测量植入扭矩、取出扭矩、植入能量和取出能量。其余4只兔子通过微型计算机断层扫描(micro-CT)和骨组织形态计量学进行分析。结果。在对照组和糖尿病组中,自钻型组的总植入能量均高于自攻型组。在自钻型和自攻型组中,糖尿病组骨髓中的小梁间距均大于对照组。Micro-CT分析显示胫骨骨质恶化,尤其是糖尿病兔的骨髓。然而,在对照组和糖尿病组中,自钻型组和自攻型组在其余测量指标上均无统计学显著相关性。结论。1型糖尿病和微型种植体的植入方法不影响微型种植体的初期稳定性。