Suppr超能文献

中国空调系统滤网中的粉螨过敏原。

Acaroid mite allergens from the filters of air-conditioning system in China.

作者信息

Li Chao-Pin, Guo Wei, Zhan Xiao-Dong, Zhao Bei-Bei, Diao Ji-Dong, Li Na, He Lian-Ping

机构信息

Department of Medical Parasitology, School of Medicine, Anhui University of Science & Technology Huainan 232001, Anhui, China ; Department of Medical Parasitology, Wannan Medical University Wuhu 241002, Anhui China.

School of Public Health, Wannan Medical College Wuhu 241002, China.

出版信息

Int J Clin Exp Med. 2014 Jun 15;7(6):1500-6. eCollection 2014.

Abstract

Accumulation of acaroid mites in the filters of air-conditioners is harmful to human health. It is important to clarify the allergen components of mites from the filters of local air-conditioning system. The present study was to detect the allergen types in the filters of air-conditioners and assesse their allergenicity by asthmatic models. Sixty aliquots of dust samples were collected from air conditioning filters in civil houses in Wuhu area. Total protein was extracted from the dust samples using PBS and quantified by Bradford method. Allergens I and II were also detected by Western blot using primary antibody (anti-Der f1/2, Der p1/Der f2/Der p2, respectively). Ten aliquots of the positive samples were randomly selected for homogenization and sensitized the mice for developing asthmatic animal models. Total serum IgE level and IFN-γ, IL-4 and IL-5 in the bronchoalveolar lavage fluid (BALF). The allergenicity of the extraction was assessed using pathological sections developed from the mouse pulmonary tissues. The concentration of extract from the 60 samples was ranged from 4.37 μg/ml to 30.76 μg/ml. After analyzing with Western blot, 31 of 60 samples were positive for 4 allergens of acaroid mites, and yet 16 were negative. The levels of total IgE from serum IL-4 and IL-5 from the BALF in the experimental group were apparently higher than that of negative control and PBS group (P < 0.01), but there were no statistical difference compared to OVA group (P > 0.05). However,the IFN-γ level in BALF was lower compared with the negative control and PBS group (P < 0.05) but with the OVA group (P > 0.05). The pathological changes were evidently emerged in pulmonary tissues, which were similar to those of OVA group, compared with the PBS ground and negative controls. The air-conditioner filters in human dwellings of Wuhu area potentially contain the major group allergen 1 and 2 from D. farinae and D. pteronyssinus, which may be associated with seasonal prevalence of allergic disorders in this area.

摘要

粉螨在空调滤网中的积聚对人体健康有害。明确当地空调系统滤网中螨虫的过敏原成分很重要。本研究旨在检测空调滤网中的过敏原类型,并通过哮喘模型评估其致敏性。从芜湖地区民用住宅的空调滤网中采集了60份灰尘样本。使用磷酸盐缓冲盐水(PBS)从灰尘样本中提取总蛋白,并通过考马斯亮蓝法进行定量。还使用一抗(分别为抗Der f1/2、Der p1/Der f2/Der p2)通过蛋白质印迹法检测过敏原I和II。随机选择10份阳性样本进行匀浆,并使小鼠致敏以建立哮喘动物模型。检测血清总IgE水平以及支气管肺泡灌洗液(BALF)中的干扰素-γ(IFN-γ)、白细胞介素-4(IL-4)和白细胞介素-5(IL-5)。使用从小鼠肺组织制作的病理切片评估提取物的致敏性。60个样本提取物的浓度范围为4.37μg/ml至30.76μg/ml。经蛋白质印迹分析,60个样本中有31个对粉螨的4种过敏原呈阳性,16个为阴性。实验组血清中总IgE水平以及BALF中IL-4和IL-5水平明显高于阴性对照组和PBS组(P<0.01),但与卵清蛋白(OVA)组相比无统计学差异(P>0.05)。然而,BALF中IFN-γ水平低于阴性对照组和PBS组(P<0.05),但与OVA组相比(P>0.05)。肺组织出现明显的病理变化,与OVA组相似,而与PBS组和阴性对照组不同。芜湖地区居民住宅的空调滤网中可能含有来自粉尘螨和屋尘螨的主要组过敏原1和2,这可能与该地区过敏性疾病的季节性流行有关。

相似文献

2
Air-conditioner filters enriching dust mites allergen.空调滤网会富集尘螨过敏原。
Int J Clin Exp Med. 2015 Mar 15;8(3):4539-44. eCollection 2015.
7
Detection of Dermatophagoides farinae in the dust of air conditioning filters.在空调滤网灰尘中检测到粉尘螨。
Int Arch Allergy Immunol. 2007;144(1):85-90. doi: 10.1159/000102619. Epub 2006 Aug 10.

引用本文的文献

本文引用的文献

1
Progress in the management of childhood asthma.儿童哮喘管理的进展
Asia Pac Allergy. 2012 Jan;2(1):15-25. doi: 10.5415/apallergy.2012.2.1.15. Epub 2012 Jan 31.
3
Allergic rhinitis in the child and associated comorbidities.儿童变应性鼻炎及相关共病。
Pediatr Allergy Immunol. 2010 Feb;21(1 Pt 2):e107-13. doi: 10.1111/j.1399-3038.2009.00933.x. Epub 2009 Aug 2.
6
The development of allergic inflammation.变应性炎症的发展
Nature. 2008 Jul 24;454(7203):445-54. doi: 10.1038/nature07204.
7
Environmental issues in managing asthma.哮喘管理中的环境问题
Respir Care. 2008 May;53(5):602-15; discussion 616-7.
9
Detection of Dermatophagoides farinae in the dust of air conditioning filters.在空调滤网灰尘中检测到粉尘螨。
Int Arch Allergy Immunol. 2007;144(1):85-90. doi: 10.1159/000102619. Epub 2006 Aug 10.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验