Pereault Marcelle, Alles Susan, Caballero Oscar, Sarver Ron, McDougal Susan, Mozola Mark, Rice Jennifer
J AOAC Int. 2014 Jul-Aug;97(4):1084-91. doi: 10.5740/jaoacint.13-181.
A study was carried out to determine the efficacy of the Soleris Direct Yeast and Mold (DYM) automated growth-based method for semiquantitative detection of yeast and mold in a variety of food products. A probability of detection (POD) statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with plate counts determined using the U.S. Food and Drug Administration Bacteriological Analytical Manual, Chapter 18, dilution plating procedure. Fourteen naturally contaminated food products were tested, with Soleris testing performed at three or more threshold levels for each food. Using the POD model, the majority of Soleris test results were in statistical agreement with the reference plating procedures. The exceptions included a single threshold level in yogurt, black pepper, dried fruit, and dry pet food, and two levels in nonfat dry milk and saw palmetto powder. In all but one of these instances, the exception being pet food, the statistical disagreement was due to Soleris estimating a higher level of contamination than the reference method. Results of ruggedness testing showed that the Soleris method produced accurate results even when significant variances in a critical operating parameter, incubation temperature, were introduced. Results of the internal and independent laboratory validation studies showed that the Soleris DYM method can be used as an accurate alternative to conventional dilution plating procedures for evaluation of yeast and mold counts at threshold levels, while saving as much as 72 h in analysis time.
开展了一项研究,以确定Soleris Direct Yeast and Mold(DYM)基于生长的自动化方法在多种食品中半定量检测酵母和霉菌的功效。使用检测概率(POD)统计模型,将Soleris在多个测试阈值(稀释度)下的结果与使用美国食品药品监督管理局《细菌学分析手册》第18章稀释平板法测定的平板计数结果进行比较。对14种天然污染的食品进行了测试,每种食品在三个或更多阈值水平下进行Soleris检测。使用POD模型,Soleris的大多数测试结果与参考平板法在统计上一致。例外情况包括酸奶、黑胡椒、干果和干宠物食品中的单个阈值水平,以及脱脂奶粉和锯叶棕粉中的两个水平。在所有这些情况中,除了宠物食品这一例外,统计上的不一致是由于Soleris估计的污染水平高于参考方法。耐用性测试结果表明,即使在关键操作参数(培养温度)引入显著差异的情况下,Soleris方法仍能产生准确的结果。内部和独立实验室验证研究的结果表明,Soleris DYM方法可作为传统稀释平板法的准确替代方法,用于评估阈值水平下的酵母和霉菌计数,同时可节省多达72小时的分析时间。