种植体植入部位的CT值与皮质骨厚度之间的关系以及不同种植体类型的初期种植体稳定性比较

Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types.

作者信息

Howashi Miori, Tsukiyama Yoshihiro, Ayukawa Yasunori, Isoda-Akizuki Kei, Kihara Masafumi, Imai Yu, Sogo Motofumi, Koyano Kiyoshi

机构信息

Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University, Fukuoka, Japan.

Division of Prosthodontics and Oral Rehabilitation, Osaka University Graduate School of Dentistry, Osaka, Japan.

出版信息

Clin Implant Dent Relat Res. 2016 Feb;18(1):107-16. doi: 10.1111/cid.12261. Epub 2014 Sep 2.

Abstract

BACKGROUND

Studies have shown that bone quality at the implant recipient site can influence primary stability.

PURPOSE

The aims of this study were to explore the quantitative estimation of the primary stability of implants preoperatively using CT values and to examine the effect of different implant designs with recommended socket preparation on primary stability.

MATERIALS AND METHODS

Forty-four fresh porcine femoral heads were prepared. The bone surrounding implant sockets was preoperatively evaluated by helical CT. Forty-four implants (φ 4.3 × 10 mm), 22 straight and 22 tapered, were placed according to the manufacturer's instructions. The insertion torque value (ITV), implant stability quotient (ISQ), and removal torque value (RTV) were recorded as indicators of primary implant stability.

RESULTS

Significant correlations and linear relationships were found between the CT value and ITV, ISQ, and RTV for both straight and tapered implants (Spearman's correlation coefficient, p < .001; linear regression analysis, p < .01). Tapered implants had a significantly higher ITV than straight implants (analysis of covariance, p < .01).

CONCLUSIONS

Obtained results suggest that the primary stability of implants could be quantitatively estimated using the CT value preoperatively, indicating the CT value of bone surrounding an implant can contribute considerably to implant planning and design choice in clinical situations.

摘要

背景

研究表明,种植体植入部位的骨质量会影响初期稳定性。

目的

本研究旨在探讨术前使用CT值对种植体初期稳定性进行定量评估,并研究不同种植体设计及推荐的牙槽窝预备方式对初期稳定性的影响。

材料与方法

准备44个新鲜猪股骨头。术前通过螺旋CT对种植体牙槽窝周围的骨进行评估。按照制造商的说明植入44枚种植体(直径4.3×10mm),其中22枚为直形,22枚为锥形。记录植入扭矩值(ITV)、种植体稳定性商数(ISQ)和取出扭矩值(RTV)作为种植体初期稳定性的指标。

结果

对于直形和锥形种植体,CT值与ITV、ISQ和RTV之间均存在显著的相关性和线性关系(Spearman相关系数,p <.001;线性回归分析,p <.01)。锥形种植体的ITV显著高于直形种植体(协方差分析,p <.01)。

结论

研究结果表明,术前可使用CT值对种植体的初期稳定性进行定量评估,这表明种植体周围骨的CT值在临床情况下对种植体规划和设计选择有很大帮助。