Suppr超能文献

用于MRI引导下经会阴前列腺活检的多切片到容积配准

Multi-slice-to-volume registration for MRI-guided transperineal prostate biopsy.

作者信息

Xu Helen, Lasso Andras, Fedorov Andriy, Tuncali Kemal, Tempany Clare, Fichtinger Gabor

机构信息

School of Computing, Queen's University, Kingston, Canada,

出版信息

Int J Comput Assist Radiol Surg. 2015 May;10(5):563-72. doi: 10.1007/s11548-014-1108-7. Epub 2014 Sep 6.

Abstract

PURPOSE

Prostate needle biopsy is a commonly performed procedure since it is the most definitive form of cancer diagnosis. Magnetic resonance imaging (MRI) allows target-specific biopsies to be performed. However, needle placements are often inaccurate due to intra-operative prostate motion and the lack of motion compensation techniques. This paper detects and determines the extent of tissue displacement during an MRI-guided biopsy so that the needle insertion plan can be adjusted accordingly.

METHODS

A multi-slice-to-volume registration algorithm was developed to align the pre-operative planning image volume with three intra-operative orthogonal image slices of the prostate acquired immediately before needle insertion. The algorithm consists of an initial rigid transformation followed by a deformable step.

RESULTS

A total of 14 image sets from 10 patients were studied. Based on prostate contour alignment, the registrations were accurate to within 2 mm.

CONCLUSION

This algorithm can be used to increase the needle targeting accuracy by alerting the clinician if the biopsy target has moved significantly prior to needle insertion. The proposed method demonstrated feasibility of intra-operative target localization and motion compensation for MRI-guided prostate biopsy.

摘要

目的

前列腺穿刺活检是一种常用的操作,因为它是癌症诊断最具决定性的形式。磁共振成像(MRI)允许进行靶向特异性活检。然而,由于术中前列腺运动以及缺乏运动补偿技术,针的放置往往不准确。本文检测并确定MRI引导活检过程中组织位移的程度,以便相应地调整针插入计划。

方法

开发了一种多切片到体积配准算法,将术前规划图像体积与针插入前立即获取的前列腺的三个术中正交图像切片对齐。该算法包括初始刚性变换,随后是可变形步骤。

结果

共研究了来自10名患者的14组图像。基于前列腺轮廓对齐,配准精度在2毫米以内。

结论

如果活检靶点在针插入前有显著移动,该算法可用于提醒临床医生,从而提高针靶向的准确性。所提出的方法证明了MRI引导前列腺活检术中靶点定位和运动补偿的可行性。

相似文献

1
Multi-slice-to-volume registration for MRI-guided transperineal prostate biopsy.
Int J Comput Assist Radiol Surg. 2015 May;10(5):563-72. doi: 10.1007/s11548-014-1108-7. Epub 2014 Sep 6.
2
Target motion compensation in MRI-guided prostate biopsy with static images.
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:5416-9. doi: 10.1109/IEMBS.2010.5626497.
3
Accuracy analysis in MRI-guided robotic prostate biopsy.
Int J Comput Assist Radiol Surg. 2013 Nov;8(6):937-44. doi: 10.1007/s11548-013-0831-9. Epub 2013 Mar 27.
5
Target motion tracking in MRI-guided transrectal robotic prostate biopsy.
IEEE Trans Biomed Eng. 2011 Nov;58(11):3135-42. doi: 10.1109/TBME.2011.2163633. Epub 2011 Aug 4.
6
Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions.
Int J Comput Assist Radiol Surg. 2020 Oct;15(10):1673-1684. doi: 10.1007/s11548-020-02226-8. Epub 2020 Jul 16.
8
Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.
Med Phys. 2017 Sep;44(9):4708-4723. doi: 10.1002/mp.12441. Epub 2017 Aug 8.
9
In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.
Phys Med Biol. 2012 Sep 21;57(18):5823-40. doi: 10.1088/0031-9155/57/18/5823. Epub 2012 Sep 5.

引用本文的文献

1
Deformable Slice-to-Volume Registration for Motion Correction of Fetal Body and Placenta MRI.
IEEE Trans Med Imaging. 2020 Sep;39(9):2750-2759. doi: 10.1109/TMI.2020.2974844. Epub 2020 Feb 18.
2
Slice-to-volume deformable registration: efficient one-shot consensus between plane selection and in-plane deformation.
Int J Comput Assist Radiol Surg. 2015 Jun;10(6):791-800. doi: 10.1007/s11548-015-1205-2. Epub 2015 Apr 23.

本文引用的文献

1
Accuracy analysis in MRI-guided robotic prostate biopsy.
Int J Comput Assist Radiol Surg. 2013 Nov;8(6):937-44. doi: 10.1007/s11548-013-0831-9. Epub 2013 Mar 27.
2
In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.
Phys Med Biol. 2012 Sep 21;57(18):5823-40. doi: 10.1088/0031-9155/57/18/5823. Epub 2012 Sep 5.
3
Analytic regularization for landmark-based image registration.
Phys Med Biol. 2012 Mar 21;57(6):1477-98. doi: 10.1088/0031-9155/57/6/1477. Epub 2012 Mar 5.
4
Target motion tracking in MRI-guided transrectal robotic prostate biopsy.
IEEE Trans Biomed Eng. 2011 Nov;58(11):3135-42. doi: 10.1109/TBME.2011.2163633. Epub 2011 Aug 4.
5
The contemporary concept of significant versus insignificant prostate cancer.
Eur Urol. 2011 Aug;60(2):291-303. doi: 10.1016/j.eururo.2011.05.006. Epub 2011 May 17.
6
Strategies for repeat prostate biopsies.
Curr Urol Rep. 2009 May;10(3):172-8. doi: 10.1007/s11934-009-0030-y.
7
MR-guided biopsy of the prostate: an overview of techniques and a systematic review.
Eur Urol. 2008 Sep;54(3):517-27. doi: 10.1016/j.eururo.2008.06.001. Epub 2008 Jun 12.
8
MR-guided prostate interventions.
J Magn Reson Imaging. 2008 Feb;27(2):356-67. doi: 10.1002/jmri.21259.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验