Suppr超能文献

用于评估近视力表现的简短意大利语句子设计。

Design of short Italian sentences to assess near vision performance.

作者信息

Calossi Antonio, Boccardo Laura, Fossetti Alessandro, Radner Wolfgang

机构信息

Department of Physics (Optics and Optometry), University of Florence, Italy; School of Optics and Optometry I.R.S.O.O., Vinci, Italy.

School of Optics and Optometry I.R.S.O.O., Vinci, Italy.

出版信息

J Optom. 2014 Oct-Dec;7(4):203-9. doi: 10.1016/j.optom.2014.05.001. Epub 2014 Jun 21.

Abstract

PURPOSE

To develop and validate 28 short Italian sentences for the construction of the Italian version of the Radner Reading Chart to simultaneously measure near visual acuity and reading speed.

METHODS

41 sentences were constructed in Italian language, following the procedure defined by Radner, to obtain "sentence optotypes" with comparable structure and with the same lexical and grammatical difficulty. Sentences were statistically selected and used in 211 normal, non-presbyopic, native Italian-speaking persons. The most equally matched sentences in terms of reading speed and number of reading errors were selected. To assess the validity of the reading speed results obtained with the 28 selected short sentences, we compared the reading speed and reading errors with the average obtained by reading two long 4th-grade paragraphs (97 and 90 words) under the same conditions.

RESULTS

The overall mean reading speed of the tested persons was 189±26wpm. The 28 sentences more similar in terms of reading times were selected, achieving a coefficient of variation (the relative SD) of 2.2%. The reliability analyses yielded an overall Cronbach's alpha coefficient of 0.98. The correlation between the short sentences and the long paragraph was high (r=0.85, P<0.0001).

CONCLUSIONS

The 28 short single Italian sentences optotypes were highly comparable in syntactical structure, number, position, and length of words, lexical difficulty, and reading length. The resulting Italian Radner Reading Chart is precise (high consistency) and practical (short sentences) and therefore useful for research and clinical practice to simultaneously measure near reading acuity and reading speed.

摘要

目的

开发并验证28个意大利语短句,用于构建意大利语版拉德纳阅读图表,以同时测量近视力和阅读速度。

方法

按照拉德纳定义的程序,用意大利语构建了41个句子,以获得结构可比、词汇和语法难度相同的“句子视标”。对句子进行统计学筛选,并在211名正常、非老花眼、以意大利语为母语的人群中使用。选择了阅读速度和阅读错误数量最匹配的句子。为评估用28个选定短句获得的阅读速度结果的有效性,我们将阅读速度和阅读错误与在相同条件下阅读两段四年级长段落(97和90个单词)的平均结果进行了比较。

结果

受测者的总体平均阅读速度为189±26词/分钟。选择了阅读时间最相似的28个句子,变异系数(相对标准差)为2.2%。可靠性分析得出总体克朗巴哈α系数为0.98。短句与长段落之间的相关性很高(r = 0.85,P < 0.0001)。

结论

28个简短的意大利语单句视标在句法结构、单词数量、位置和长度、词汇难度以及阅读长度方面具有高度可比性。由此产生的意大利语拉德纳阅读图表精确(高度一致性)且实用(短句),因此对于同时测量近阅读视力和阅读速度的研究及临床实践很有用。

相似文献

6
The validity and reliability of short German sentences for measuring reading speed.用于测量阅读速度的简短德语句子的有效性和可靠性。
Graefes Arch Clin Exp Ophthalmol. 2002 Jun;240(6):461-7. doi: 10.1007/s00417-002-0443-5. Epub 2002 Mar 16.
7
A new principle for the standardization of long paragraphs for reading speed analysis.一种用于阅读速度分析的长段落标准化新原则。
Graefes Arch Clin Exp Ophthalmol. 2016 Jan;254(1):177-84. doi: 10.1007/s00417-015-3207-8. Epub 2015 Nov 5.

引用本文的文献

7
Development and Validation of the Persian Version of the MNREAD Acuity Chart.MNREAD视力表波斯语版本的开发与验证
J Curr Ophthalmol. 2020 Jul 4;32(3):274-280. doi: 10.4103/JOCO.JOCO_80_20. eCollection 2020 Jul-Sep.
9
Functional assessment of a new extended depth-of-focus intraocular lens.新的扩展景深人工晶状体的功能评估。
Eye (Lond). 2019 Mar;33(3):404-410. doi: 10.1038/s41433-018-0221-1. Epub 2018 Sep 28.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验