Suppr超能文献

标准化阅读图表系统的可靠性:方差成分分析、重测信度和图表间信度

Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability.

作者信息

Stifter Eva, König Franz, Lang Thomas, Bauer Peter, Richter-Müksch Sibylla, Velikay-Parel Michaela, Radner Wolfgang

机构信息

Department of Ophthalmology and Optometry, University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2004 Jan;242(1):31-9. doi: 10.1007/s00417-003-0776-8. Epub 2003 Dec 10.

Abstract

BACKGROUND

The purpose of this study was to analyze statistically the test-retest and inter-chart reliability of three standardized Radner Reading Charts with respect to reading acuity, maximum reading speed, critical print size and LogRAD/LogMAR ratio and to quantitatively identify the sources of variability.

METHODS

At two testing sessions (3 to 4 weeks apart), 36 volunteers read monocularly all three Radner Reading Charts in randomized order (orthogonal Latin square design). The subjects were grouped according to their distance LogMAR visual acuity (group 1, 0.1 or better; group 2, 0.12-0.4; group 3, 0.42-0.8). Based on these 216 reading tests, crude correlations were calculated between the two testing sessions and between the three charts, and "variance component analyses" were performed for all variables.

RESULTS

For all visual acuity groups and variables, the test-retest and the inter-chart reliability was high. The variance component analyses showed that the differences between individuals predominantly influenced the variance, whereas the effect of the test replication was low. The three charts caused minimal variability, indicating equality for clinical examinations.

CONCLUSION

The standardized Radner Reading Charts provide clinically reliable and reproducible results for individuals with normal eyesight and for patients with visual impairment. These findings indicate that reading test systems, which consider the current international standards for visual acuity measurements (EN ISO 8596, NAS-NRC) and the psychophysical requirements for controlling optical item interactions, can provide reliable measures for clinical and scientific analyses of reading performance.

摘要

背景

本研究旨在对三种标准化的拉德纳阅读图表在阅读敏锐度、最大阅读速度、临界印刷字体大小和LogRAD/LogMAR比率方面的重测信度和图表间信度进行统计学分析,并定量确定变异性来源。

方法

在两次测试 session(间隔3至4周)中,36名志愿者单眼以随机顺序(正交拉丁方设计)阅读所有三种拉德纳阅读图表。受试者根据其远距离LogMAR视力分组(第1组,0.1或更好;第2组,0.12 - 0.4;第3组,0.42 - 0.8)。基于这216次阅读测试,计算两次测试session之间以及三张图表之间的原始相关性,并对所有变量进行“方差成分分析”。

结果

对于所有视力组和变量,重测信度和图表间信度都很高。方差成分分析表明,个体间差异对变异性的影响最大,而测试重复的影响较小。三张图表引起的变异性最小,表明在临床检查中具有等效性。

结论

标准化的拉德纳阅读图表为视力正常者和视力受损患者提供了临床可靠且可重复的结果。这些发现表明,考虑到当前国际视力测量标准(EN ISO 8596,NAS - NRC)以及控制光学物品相互作用的心理物理学要求的阅读测试系统,可以为阅读性能的临床和科学分析提供可靠的测量方法。