Suppr超能文献

清洁方法对聚酰胺义齿基托材料三维表面粗糙度、光泽度和颜色的影响。

Effects of cleansing methods on 3-D surface roughness, gloss and color of a polyamide denture base material.

作者信息

Polychronakis Nick C, Polyzois Gregory L, Lagouvardos Panagiotis E, Papadopoulos Triantafillos D

机构信息

Department of Prosthodontics.

出版信息

Acta Odontol Scand. 2015 Jul;73(5):353-63. doi: 10.3109/00016357.2014.967720. Epub 2014 Nov 4.

Abstract

OBJECTIVE

The purpose of this study was to determine the effects of two denture cleansing methods on 3-D surface roughness, gloss and color of denture base materials.

MATERIALS AND METHODS

Thirty disks from nylon (Valplast) and 30 from heat-polymerized acrylic denture base material (Paladon 65) were made and 10 of each material were immersed in water (control), Val-Clean (peroxide cleanser) and Corega Extradent (peroxide cleanser) plus microwaving for a period simulating 30 days of daily cleansing. 3-D surface roughness, gloss and color parameters were measured before and after cleansing using an interferometric profilometer, a gloss meter and a colorimeter. The results were statistically analysed by regression, paired-t, Mann-Whitney and Kruskal-Wallis tests at α = 0.05 level of significance.

RESULTS

The results showed significant differences at baseline in L* and b* parameters between materials (p < 0.01), with a significantly lower gloss (p < 0.05) and higher roughness (p < 0.05) for Valplast. After cleansing, Δϵ* was significantly greater in Valplast than Paladon 65 (p < 0.05). Gloss of both materials decreased significantly within the Corega Extradent plus microwave solution (p < 0.05), while roughness increased significantly only for Paladon 65 (p < 0.05).

CONCLUSIONS

Valplast was found to have a significantly lower gloss and a higher roughness than Paladon 65 before cleansing. After cleansing, ΔE* increased more in Valplast than in Paladon 65, gloss of both materials decreased and roughness only of Paladon 65 increased within the Corega extradent plus microwaving method.

摘要

目的

本研究旨在确定两种义齿清洁方法对义齿基托材料三维表面粗糙度、光泽度和颜色的影响。

材料与方法

制作30个尼龙(Valplast)圆盘和30个热聚合丙烯酸义齿基托材料(Paladon 65)圆盘,每种材料各10个分别浸泡在水中(对照组)、Val-Clean(过氧化物清洁剂)以及Corega Extradent(过氧化物清洁剂)中,并进行微波处理,模拟每日清洁30天的时间。在清洁前后,使用干涉轮廓仪、光泽度仪和色度计测量三维表面粗糙度、光泽度和颜色参数。结果采用回归分析、配对t检验、曼-惠特尼检验和克鲁斯卡尔-沃利斯检验进行统计学分析,显著性水平α = 0.05。

结果

结果显示,材料之间在基线时L和b参数存在显著差异(p < 0.01),Valplast的光泽度显著较低(p < 0.05),粗糙度较高(p < 0.05)。清洁后,Valplast的Δϵ*显著大于Paladon 65(p < 0.05)。在Corega Extradent加微波溶液中,两种材料的光泽度均显著降低(p < 0.05),而仅Paladon 65的粗糙度显著增加(p < 0.05)。

结论

发现Valplast在清洁前的光泽度显著低于Paladon 65,粗糙度更高。清洁后,Valplast的ΔE*增加幅度大于Paladon 65,两种材料的光泽度均降低,且在Corega Extradent加微波处理方法中,仅Paladon 65的粗糙度增加。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验