使用单光子发射计算机断层扫描(SPECT)对锝-99m二巯基丁二酸(DMSA)的肾脏摄取进行定量分析。

Quantitation of renal uptake of technetium-99m DMSA using SPECT.

作者信息

Groshar D, Frankel A, Iosilevsky G, Israel O, Moskovitz B, Levin D R, Front D

机构信息

Division of Nuclear Medicine, Rebecca Sieff Government Hospital, Safed, Israel.

出版信息

J Nucl Med. 1989 Feb;30(2):246-50.

PMID:2544692
Abstract

Quantitative single photon emission computed tomography (SPECT) methodology based on calibration with kidney phantoms has been applied for the assessment of renal uptake of [99mTc]DMSA in 25 normals; 16 patients with a single normal kidney; 30 patients with unilateral nephropathy; and 17 patients with bilateral nephropathy. An excellent correlation (r = 0.99, s.e.e. = 152) was found between SPECT measured concentration and actual concentration in kidney phantoms. Kidney uptake at 6 hr after injection in normals was 20.0% +/- 4.6% for the left and 20.8% +/- 4.4% for the right. Patients with unilateral nephropathy had a statistically significant (p less than 0.001) low uptake in the diseased kidney (7.0% +/- 4.7%), but the contralateral kidney uptake did not differ from the normal group (20.0% +/- 7.0%). The method was especially useful in patients with bilateral nephropathy. Significantly (p less than 0.001) decreased uptake was found in both kidneys (5.1% +/- 3.4% for the left and 6.7% +/- 4.2% for the right). The total kidney uptake (right and left) in this group showed to be inversely correlated (r = 0.83) with serum creatinine. The uptake of [99mTc]DMSA in single normal kidney was higher (p less than 0.001) than in a normal kidney (34.7% +/- 11.9%), however, it was lower than the total absolute uptake (RT + LT = 41.5% +/- 8.8%) in the normal group. The results indicate that SPECT is a reliable and reproducible technique to quantitate absolute kidney uptake of [99mTc]DMSA.

摘要

基于肾脏模型校准的定量单光子发射计算机断层扫描(SPECT)方法已应用于评估25名正常人、16名单侧正常肾患者、30名单侧肾病患者和17名双侧肾病患者肾脏对[99mTc]二巯基丁二酸(DMSA)的摄取情况。SPECT测量的浓度与肾脏模型中的实际浓度之间存在极好的相关性(r = 0.99,标准误差 = 152)。正常情况下,注射后6小时左肾摄取率为20.0%±4.6%,右肾为20.8%±4.4%。单侧肾病患者患病肾脏的摄取率显著降低(p < 0.001)(7.0%±4.7%),但对侧肾脏摄取率与正常组无差异(20.0%±7.0%)。该方法对双侧肾病患者尤其有用。双侧肾脏摄取率均显著降低(p < 0.001)(左肾为5.1%±3.4%,右肾为6.7%±4.2%)。该组患者的双侧肾脏总摄取率与血清肌酐呈负相关(r = 0.83)。单例正常肾对[99mTc]DMSA的摄取率高于正常肾脏中的一个(p < 0.001)(34.7%±11.9%),但低于正常组的双侧肾脏总绝对摄取率(RT + LT = 41.5%±8.8%)。结果表明,SPECT是一种可靠且可重复的技术,可用于定量[99mTc]DMSA在肾脏的绝对摄取量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验