Suppr超能文献

根管弯曲度对电子根尖定位仪准确性的影响:一项体外研究。

Influence of root canal curvature on the accuracy of an electronic apex locator: An in vitro study.

作者信息

Santhosh Lekha, Raiththa Pooja, Aswathanarayana Srirekha, Panchajanya Srinivas, Reddy Jayakumar Thimmaraya, Susheela Shwetha Rajanna

机构信息

Department of Conservative Dentistry and Endodontics, The Oxford Dental College, Bommanahalli, Bangalore, Karnataka, India.

出版信息

J Conserv Dent. 2014 Nov;17(6):583-6. doi: 10.4103/0972-0707.144610.

Abstract

OBJECTIVE

This study investigated whether the canal curvature has an influence on the accuracy of Electronic Apex Locator.

MATERIALS AND METHODS

Sixty mandibular posterior teeth were decoronated. A number (No.) 10 file was inserted into the mesiobuccal canal and radiographs were taken to determine the degree of curvature by Schneider's method. Samples were divided into three groups of mild (<20°), moderate (20-36°) and severe curvature (>36°). After enlarging the orifice, the actual canal length was determined by introducing a file until the tip emerged through the major foramen when observed under 20X magnification. The teeth were embedded in an alginate model and the Root ZX was used to determine the electronic length. The data was analyzed by Kruskal-Wallis test followed by Mann-Whitney test.

RESULTS

The difference in measurement of Actual and Electronic working length was statistically significant between group 1 and 2 (P < 0.05) as well as between group 1 and group 3 (P < 0.05) with group 1 showing the lowest difference.

CONCLUSION

Considering ± 0.5 mm as tolerance limit for accuracy, the device was 95% accurate for the mild curvature group and 80% accurate for moderate and severe groups.

摘要

目的

本研究调查根管弯曲度是否对电子根尖定位仪的准确性有影响。

材料与方法

选取60颗下颌后牙截冠。将10号锉插入近中颊根管,通过施奈德法拍摄X线片以确定弯曲度。样本分为轻度(<20°)、中度(20 - 36°)和重度弯曲(>36°)三组。扩大根管口后,通过插入锉直至在20倍放大倍数下观察到锉尖穿出主根尖孔来确定实际根管长度。将牙齿嵌入藻酸盐模型中,使用Root ZX测定电子长度。数据采用Kruskal - Wallis检验,随后进行Mann - Whitney检验。

结果

第1组与第2组以及第1组与第3组之间实际工作长度和电子工作长度测量值的差异具有统计学意义(P < 0.05),第1组差异最小。

结论

以±0.5 mm作为准确性的公差限度,该设备对轻度弯曲组的准确率为95%,对中度和重度弯曲组的准确率为80%。

相似文献

1
Influence of root canal curvature on the accuracy of an electronic apex locator: An in vitro study.
J Conserv Dent. 2014 Nov;17(6):583-6. doi: 10.4103/0972-0707.144610.
2
Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An Study.
Iran Endod J. 2017 Spring;12(2):173-178. doi: 10.22037/iej.2017.34.
3
Accuracy of a new apex locator: an in vitro study.
Int Endod J. 2002 Feb;35(2):186-92. doi: 10.1046/j.1365-2591.2002.00468.x.
4
Accuracy of an electronic apex locator in primary teeth with root resorption.
Int Endod J. 2009 Feb;42(2):115-21. doi: 10.1111/j.1365-2591.2008.01476.x.
5
Critical diameter of apical foramen and of file size using the Root ZX apex locator: an in vitro study.
J Endod. 2011 Sep;37(9):1306-9. doi: 10.1016/j.joen.2011.05.007. Epub 2011 Jul 16.
6
Influence of tooth length on the accuracy of the Root ZX electronic apical foramen locator: an ex vivo study.
Acta Odontol Scand. 2015 Feb;73(2):101-6. doi: 10.3109/00016357.2014.956144. Epub 2014 Oct 9.
8
Accuracy of an electronic apex locator: a clinical evaluation in primary molars with and without resorption.
J Clin Pediatr Dent. 2011 Spring;35(3):255-8. doi: 10.17796/jcpd.35.3.7w71656740286960.
9
A comparison between two electronic apex locators: an ex vivo investigation.
Int Endod J. 2007 May;40(5):362-73. doi: 10.1111/j.1365-2591.2006.01229.x. Epub 2007 Feb 19.
10
The accuracy of root canal measurements using the Mini Apex Locator and Root ZX-II: an evaluation in vitro.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Sep;104(3):e50-3. doi: 10.1016/j.tripleo.2007.03.025.

引用本文的文献

1
Factors influencing the accuracy of electronic apex locators: A scoping review.
Dent Res J (Isfahan). 2025 Jun 27;22:26. doi: 10.4103/drj.drj_634_23. eCollection 2025.
3
evaluation of the accuracy of four electronic foraminal locators.
J Clin Exp Dent. 2024 Jan 1;16(1):e18-e24. doi: 10.4317/jced.61003. eCollection 2024 Jan.
4
Apexoconnection: A Novel Technique to Determine Working Length.
Clin Cosmet Investig Dent. 2021 Aug 17;13:353-360. doi: 10.2147/CCIDE.S316839. eCollection 2021.
5
Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An Study.
Iran Endod J. 2017 Spring;12(2):173-178. doi: 10.22037/iej.2017.34.

本文引用的文献

1
An in vitro comparison of root canal length determination by DentaPort ZX and iPex apex locators.
J Conserv Dent. 2013 Nov;16(6):555-8. doi: 10.4103/0972-0707.120953.
2
Efficiency of 2 electronic apex locators on working length determination: A clinical study.
J Conserv Dent. 2013 May;16(3):229-32. doi: 10.4103/0972-0707.111320.
4
Effectiveness of four electronic apex locators to determine distance from the apical foramen.
Int Endod J. 2010 Sep;43(9):808-17. doi: 10.1111/j.1365-2591.2010.01765.x. Epub 2010 Aug 3.
7
The fundamental operating principles of electronic root canal length measurement devices.
Int Endod J. 2006 Aug;39(8):595-609. doi: 10.1111/j.1365-2591.2006.01131.x.
9
A comparison between two electronic apex locators: an in vivo investigation.
Int Endod J. 2005 Jan;38(1):36-45. doi: 10.1111/j.1365-2591.2004.00899.x.
10
In vitro evaluation of the accuracy of three electronic apex locators.
J Endod. 2004 Apr;30(4):231-3. doi: 10.1097/00004770-200404000-00012.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验