Suppr超能文献

显微CT对男性耳郭表面后部小梁骨评估的贡献。

The contribution of Micro-CT to the evaluation of trabecular bone at the posterior part of the auricular surface in men.

作者信息

Deguette Céline, Chappard Daniel, Libouban Hélène, Airagnes Guillaume, Rouge-Maillart Clotilde, Telmon Norbert

机构信息

CHU Angers, Department of Forensic Medicine, LUNAM Université, Angers Cedex, France.

GEROM Groupe Etudes Remodelage Osseux et bioMatériaux, LUNAM Université, IRIS-IBS Institut de Biologie en Santé, CHU d'Angers, 49933, Angers Cedex, France.

出版信息

Int J Legal Med. 2018 Jul;132(4):1231-1239. doi: 10.1007/s00414-014-1139-1. Epub 2014 Dec 24.

Abstract

AIM

Using multi-slice computed tomography (MSCT), Barrier et al. described the disappearance at the posterior auricular surface of a "central line" (CL) and "juxtalinear cells" (JLCs) belonging to a trabecular bundle, and a trabecular density gradient around the CL that decreased with age. The aim of our study was to use micro-CT to test these findings, referring to the concept of Ascadi and Nemeskeri.

METHODOLOGY

The coxal bones of fifteen males were used; age was known. CLs were identified on MSCT-sections using Barrier's method (64 detectors, 0.6 mm slice thickness, 0.1 mm overlap) with two different software programs (Synapse®, Amira®). Then, CLs were researched on microCT slices (pixel size: 36 μm). Three volumes of interest were defined (around, above, and below CL), and 3D morphometric parameters of the trabecular microarchitecture (particularly BV/TV and DA) were calculated. Two-tailed statistical analyses were performed attempting to correlate these parameters with age at death.

RESULTS

CLs and JLCs were observed on micro-CT slices, but with moderate agreement between both imaging techniques. Their presence was not correlated with the age of the subjects. Around the CL, BV/TV decreased significantly with age; DA was negatively correlated with BV/TV and had a tendency to increase with age. Between areas above and below the CL, there was a BV/TV gradient and both BV/TVs decreased in parallel with age.

CONCLUSION

Our findings regarding the contribution of micro-CT to the evaluation of trabecular bone could be a promising research approach for application in a larger study population.

摘要

目的

Barrier等人使用多层螺旋计算机断层扫描(MSCT)描述了属于小梁束的“中心线”(CL)和“近线性细胞”(JLCs)在耳后表面的消失,以及CL周围小梁密度梯度随年龄下降的情况。我们研究的目的是使用显微CT参照Ascadi和Nemeskeri的概念来验证这些发现。

方法

使用了15名男性的髋骨,年龄已知。使用Barrier方法(64排探测器,层厚0.6毫米,重叠0.1毫米)在MSCT切片上使用两个不同的软件程序(Synapse®,Amira®)识别CL。然后,在显微CT切片(像素大小:36μm)上研究CL。定义了三个感兴趣的体积(CL周围、上方和下方),并计算了小梁微结构的三维形态计量学参数(特别是骨体积分数和骨小梁间距)。进行双尾统计分析,试图将这些参数与死亡年龄相关联。

结果

在显微CT切片上观察到了CL和JLC,但两种成像技术之间的一致性一般。它们的存在与受试者的年龄无关。在CL周围,骨体积分数随年龄显著下降;骨小梁间距与骨体积分数呈负相关,且有随年龄增加的趋势。在CL上方和下方区域之间,存在骨体积分数梯度,且两个骨体积分数均随年龄平行下降。

结论

我们关于显微CT在小梁骨评估中的作用的发现可能是一种有前途的研究方法,可应用于更大的研究人群。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验