Song Diagnostic Research LLC, 1 Megans Lane, Woodside, CA 94062, USA.
Biosensors (Basel). 2013 Oct 21;3(4):360-73. doi: 10.3390/bios3040360.
We demonstrate a fluorescence lateral flow system that has excellent sensitivity and wide dynamic range. The illumination system utilizes an LED, plastic lenses and plastic and colored glass filters for the excitation and emission light. Images are collected on an iPhone 4. Several fluorescent dyes with long Stokes shifts were evaluated for their signal and nonspecific binding in lateral flow. A wide range of values for the ratio of signal to nonspecific binding was found, from 50 for R-phycoerythrin (R-PE) to 0.15 for Brilliant Violet 605. The long Stokes shift of R-PE allowed the use of inexpensive plastic filters rather than costly interference filters to block the LED light. Fluorescence detection with R-PE and absorbance detection with colloidal gold were directly compared in lateral flow using biotinylated bovine serum albumen (BSA) as the analyte. Fluorescence provided linear data over a range of 0.4-4,000 ng/mL with a 1,000-fold signal change while colloidal gold provided non-linear data over a range of 16-4,000 ng/mL with a 10-fold signal change. A comparison using human chorionic gonadotropin (hCG) as the analyte showed a similar advantage in the fluorescent system. We believe our inexpensive yet high-performance platform will be useful for providing quantitative and sensitive detection in a point-of-care setting.
我们展示了一种具有出色灵敏度和宽动态范围的荧光侧向流动系统。该照明系统利用 LED、塑料透镜以及塑料和有色玻璃滤光片来激发和发射光。图像由 iPhone 4 采集。我们评估了几种具有长斯托克斯位移的荧光染料,以研究它们在侧向流动中的信号和非特异性结合。我们发现信号与非特异性结合的比值范围很广,从 R-藻红蛋白(R-PE)的 50 到 Brilliant Violet 605 的 0.15。R-PE 的长斯托克斯位移允许使用廉价的塑料滤光片而不是昂贵的干涉滤光片来阻挡 LED 光。我们在侧向流动中直接比较了 R-PE 的荧光检测和胶体金的吸光度检测,以生物素化牛血清白蛋白(BSA)作为分析物。荧光检测在 0.4-4000ng/mL 范围内提供线性数据,信号变化 1000 倍,而胶体金检测在 16-4000ng/mL 范围内提供非线性数据,信号变化 10 倍。使用人绒毛膜促性腺激素(hCG)作为分析物进行的比较显示,荧光系统具有类似的优势。我们相信,我们这种廉价但高性能的平台将有助于在即时护理环境中提供定量和敏感的检测。