Abstract

BACKGROUND

To evaluate lens epithelial cell (LEC) proliferation with two different designs (one-piece or three-piece) of hydrophobic acrylic IOLs with 360° square optic edge using an in vitro culture model of posterior capsule opacification (PCO).

METHODS

This experimental study was conducted at the Department of NEUROFARBA, Section of Pharmacology, University of Florence, Italy. Human LECs were seeded and cultured in transwell cell culture inserts coated with a type-IV collagen membrane on which an IOL (one-piece Tecnis-1 or three-piece AR40E, Abbott Medical Optics Inc.) had been previously placed. As control, cells were plated on the insert membrane without an IOL. At day six (cells confluent in controls) IOLs were removed and cell counting, viability and cell density under and outside the IOLs were evaluated.

RESULTS

No statistically significant difference in the number of cells (p>0.05) between inserts with the one-piece and three-piece IOLs was found. Cell density in the area under each IOL was significantly lower than in the area outside of it (p<0.05), or in the control insert. (p<0.05). Cell density under the single-piece IOL was not significantly different from that under the three-piece IOL (p>0.05).

CONCLUSIONS

A 360° sharp-edge played a crucial role in avoiding LEC migration under the IOL and preventing the formation of PCO after cataract surgery. Long term clinical evaluation is necessary to estimate functional results.

摘要

背景

使用体外后囊混浊(PCO)培养模型,评估具有 360°方形光学边缘的两种不同设计(一件式或三件式)疏水性丙烯酸人工晶状体对晶状体上皮细胞(LEC)增殖的影响。

方法

该实验研究在意大利佛罗伦萨大学神经 FARBA 系药理学科进行。将人 LEC 接种并培养在 Transwell 细胞培养插入物上,该插入物涂覆有 IV 型胶原膜,人工晶状体(一件式 Tecnis-1 或三件式 AR40E,Abbott Medical Optics Inc.)已预先放置在该膜上。作为对照,细胞在没有人工晶状体的插入物膜上接种。在第 6 天(对照中细胞融合)时,取出人工晶状体并评估细胞计数、活力以及人工晶状体下和外部的细胞密度。

结果

未发现一件式和三件式人工晶状体插入物之间细胞数量存在统计学差异(p>0.05)。每个人工晶状体下的细胞密度明显低于其外部区域(p<0.05)或对照插入物(p<0.05)。单一件式人工晶状体下的细胞密度与三件式人工晶状体下的细胞密度无显著差异(p>0.05)。

结论

360°锐边在避免人工晶状体下 LEC 迁移和防止白内障手术后 PCO 形成方面起着至关重要的作用。需要进行长期临床评估以估计功能结果。