Suppr超能文献

危重症成年患者血气参数、二氧化碳分压差值及二氧化碳分压差值与动静脉血氧含量差的可重复性

Repeatability of blood gas parameters, PCO2 gap, and PCO2 gap to arterial-to-venous oxygen content difference in critically ill adult patients.

作者信息

Mallat Jihad, Lazkani Ali, Lemyze Malcolm, Pepy Florent, Meddour Mehdi, Gasan Gaëlle, Temime Johanna, Vangrunderbeeck Nicolas, Tronchon Laurent, Thevenin Didier

机构信息

From the Department of Anesthesiology and Critical Care Medicine (JM, AL, ML, FP, MM, GG, JT, NV, LT, DT), Centre Hospitalier du Dr Schaffner de Lens, Lens, France.

出版信息

Medicine (Baltimore). 2015 Jan;94(3):e415. doi: 10.1097/MD.0000000000000415.

Abstract

The objective of this study was to examine the repeatability of blood gas (BG) parameters and their derived variables such as the central venous-to-arterial carbon dioxide tension difference (▵PCO2) and the ratio of ▵PCO2 over the central arteriovenous oxygen content difference (▵PCO2/C(a-cv)O2) and to determine the smallest detectable changes in individual patients.A total of 192 patients with arterial and central venous catheters were included prospectively. Two subsequent arterial and central venous blood samples were collected immediately one after the other and analyzed using the same point-of-care BG analyzer. The samples were analyzed for arterial and venous BG parameters, ▵PCO2, and ▵PCO2/C(a-cv)O2 ratio. Repeatability was expressed as the smallest detectable difference (SDD) and the least significant change (LSC). A change in value of these parameters exceeding the SDD or the LSC should be regarded as real.The SDDs for arterial carbon dioxide tension, arterial oxygen saturation, central venous oxygen saturation (ScvO2), and ▵PCO2 were small: ±2.06 mm Hg, ±1.23%, 2.92%, and ±1.98 mm Hg, respectively, whereas the SDDs for arterial oxygen tension (PaO2) and ▵PCO2/C(a-cv)O2 were high: ±9.09 mm Hg and ±0.57 mm Hg/mL, respectively. The LSCs (%) for these variables were 5.06, 1.27, 4.44, 32.4, 9.51, and 38.5, respectively.The repeatability of all these variables was good except for PaO2 and ▵PCO2/C(a-cv)O2 ratio for which we observed an important inherent variability. Expressed as SDD, a ScvO2 change value of at least ±3% should be considered as true. The clinician must be aware that an apparent change in these variables in an individual patient might represent only an inherent variation.

摘要

本研究的目的是检验血气(BG)参数及其衍生变量的可重复性,如中心静脉与动脉二氧化碳分压差值(▵PCO2)以及▵PCO2与中心动静脉氧含量差值之比(▵PCO2/C(a-cv)O2),并确定个体患者中最小可检测变化。前瞻性纳入了192例留置动脉和中心静脉导管的患者。紧接着先后采集两份动脉和中心静脉血样,并使用同一台床旁BG分析仪进行分析。对样本进行动脉和静脉BG参数、▵PCO2以及▵PCO2/C(a-cv)O2比值分析。可重复性以最小可检测差值(SDD)和最小显著变化(LSC)表示。这些参数值的变化超过SDD或LSC应视为真实变化。动脉二氧化碳分压、动脉血氧饱和度、中心静脉血氧饱和度(ScvO2)和▵PCO​2的SDD较小,分别为±2.06 mmHg、±1.23%、2.92%和±1.98 mmHg,而动脉血氧分压(PaO2)和▵PCO2/C(a-cv)O2的SDD较高,分别为±9.09 mmHg和±0.57 mmHg/mL。这些变量的LSC(%)分别为5.06、1.27、4.44、32.4、9.51和38.5。除PaO2和▵PCO2/C(a-cv)O2比值外,所有这些变量的可重复性良好,我们观察到这两个指标存在较大的固有变异性。以SDD表示,ScvO2变化值至少±3%应被视为真实变化。临床医生必须意识到,个体患者这些变量的明显变化可能仅代表固有变异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3a17/4602629/b20513b7476e/medi-94-e415-g003.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验