Poggio Claudio, Dagna Alberto, Chiesa Marco, Beltrami Riccardo, Bianchi Stefano
Department of Clinical-Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Piazzale Golgi 3, 27100 Pavia, Italy.
Department of Brain and Behavioural Sciences-Section of Statistics, University of Pavia, Via Bassi 21, 27100 Pavia, Italy.
J Funct Biomater. 2015 Feb 16;6(1):66-76. doi: 10.3390/jfb6010066.
Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files allows the clinicians to produce the desirable tapered root canal form with a reduced tendency to canal transportation and instrument fracture. HyFlex CM instruments are new NiTi rotary instruments with shape memory produced by an innovative methodology (patent pending) that uses a complex heating and cooling treatment that controls the material's memory. The aim of the present study was to compare the cleaning efficacy of two conventional (Mtwo, Revo-S) Ni-Ti rotary instruments with HyFlex CM. 30 single-rooted freshly extracted teeth were divided into three groups. Root canals were shaped with three NiTi instruments (Mtwo, Revo-S and HyFlex CM) using 5.25% NaOCl and 17% EDTA solutions. Specimens were fractured longitudinally and prepared for SEM analysis at standard magnification of 1000×. The presence/absence of debris smear layer and the presence/absence of smear layer at coronal, middle, and apical third of each canal were evaluated using a 5-step scale for scores. Numeric data were analyzed using Kruskall-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05. This study revealed significant differences among the various groups. Despite some minor differences, all instruments removed smear layer and debris produced during instrumentation. HyFlex CM seem to be not so effective in promoting cleanliness of root canal walls and in removing smear layer from dentine if compared to Mtwo and Revo-S.
镍钛(NiTi)器械在牙髓病治疗中常用于根管系统的预备。与传统的不锈钢锉相比,它们更具柔韧性且切割效率更高。NiTi旋转锉的超弹性使临床医生能够制备出理想的根管锥度形态,同时减少根管偏移和器械折断的倾向。HyFlex CM器械是新型的NiTi旋转器械,采用创新方法(专利申请中)生产,具有形状记忆功能,该方法使用复杂的加热和冷却处理来控制材料的记忆特性。本研究的目的是比较两种传统的NiTi旋转器械(Mtwo、Revo-S)与HyFlex CM器械的清洁效果。30颗新鲜拔除的单根牙被分为三组。使用5.25%次氯酸钠和17%乙二胺四乙酸(EDTA)溶液,用三种NiTi器械(Mtwo、Revo-S和HyFlex CM)对根管进行预备。将标本纵向折断,制备用于扫描电子显微镜(SEM)分析的样本,标准放大倍数为1000倍。使用5级评分量表评估每个根管冠部、中部和根尖三分之一处碎屑玷污层的有无情况。数值数据采用Kruskal-Wallis检验和Mann-Whitney U检验进行分析,显著性水平预先设定为P < 0.05。本研究揭示了不同组之间存在显著差异。尽管存在一些细微差异,但所有器械都能去除预备过程中产生的玷污层和碎屑。与Mtwo和Revo-S相比,HyFlex CM在促进根管壁清洁和去除牙本质玷污层方面似乎效果欠佳。