EndoVac冲洗系统与Max-I探针在去除根管根尖1mm和3mm处玷污层效果的比较评估:一项体外扫描电子显微镜研究

Comparative evaluation of efficacy of EndoVac irrigation system to Max-I probe in removing smear layer in apical 1 mm and 3 mm of root canal: An in vitro scanning electron microscope study.

作者信息

Dua Ankur, Dua Deepti

机构信息

Department of Restorative Dentistry and Endodontics, Ibn Sina National College of Medical Studies, Jeddah, Kingdom of Saudi Arabia.

出版信息

Dent Res J (Isfahan). 2015 Jan-Feb;12(1):38-43. doi: 10.4103/1735-3327.150329.

Abstract

BACKGROUND

The purpose of this study was to compare the efficacy of EndoVac irrigation system and side-vented closed ended needle (Max-I probe) in removing smear layer from root canals at 1 mm and 3 mm from working length using ProTaper rotary instrumentation.

MATERIALS AND METHODS

A total of 50 freshly extracted maxillary central incisors were randomly divided into two groups after complete cleaning and shaping with ProTaper rotary files. In one group, final irrigation was performed with EndoVac system while in other group, final irrigation was done with a 30 gauge Max-I probe. 3% sodium hypochlorite (NaOCl) and 17% ethylenediaminetetracetic acid were used as final irrigants in all teeth. During instrumentation, 1 ml of 3% NaOCl was used for irrigation after each rotary instrument in the similar manner as in final irrigation. After instrumentation and irrigation, teeth were sectioned longitudinally into buccal and palatal halves and viewed under scanning electron microscope for evaluation of smear layer. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U-test. (P < 0.05).

RESULTS

At 3 mm level, there was no significant difference between two groups. At 1 mm level, EndoVac group showed significantly better smear layer removal compared with Max-I probe (P = 0.0001).

CONCLUSION

EndoVac system results in better smear layer removal at 1 mm from working length when compared to Max-I probe irrigation.

摘要

背景

本研究的目的是比较EndoVac冲洗系统和侧孔封闭式针头(Max - I探针)在使用ProTaper旋转器械时,从距工作长度1毫米和3毫米处的根管中去除玷污层的效果。

材料与方法

50颗新鲜拔除的上颌中切牙先用ProTaper旋转锉进行彻底清理和预备,之后随机分为两组。一组使用EndoVac系统进行最终冲洗,另一组则使用30号Max - I探针进行最终冲洗。所有牙齿均使用3%次氯酸钠(NaOCl)和17%乙二胺四乙酸作为最终冲洗液。在预备过程中,每使用一支旋转器械后,以与最终冲洗相同的方式使用1毫升3%的NaOCl进行冲洗。预备和冲洗完成后,将牙齿沿颊舌方向纵向剖开,置于扫描电子显微镜下观察玷污层情况。采用Kruskal - Wallis检验和Mann - Whitney U检验进行统计学分析(P < 0.05)。

结果

在3毫米深度时,两组之间无显著差异。在1毫米深度时,EndoVac组与Max - I探针组相比,玷污层去除效果显著更好(P = 0.0001)。

结论

与Max - I探针冲洗相比,EndoVac系统在距工作长度1毫米处能更好地去除玷污层。