PURPOSE

To evaluate intereye corneal asymmetry in Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) indices as a diagnostic method between normal patients and patients with keratoconus.

METHODS

A retrospective, observational case series of 177 healthy, 44 indeterminate, and 121 patients with keratoconus classified by Pentacam ectasia detection indices, randomized to analysis and validation datasets. Intereye asymmetry in 20 Scheimpflug tomography corneal descriptors was calculated and compared to develop diagnostic models.

RESULTS

Intereye asymmetry was not correlated with anisometropia in healthy controls but was correlated with the ectasia grade of the worse eye in patients with keratoconus. Patients with keratoconus had significantly greater intereye asymmetry in all descriptors except for relational thickness indices. Intereye asymmetry in front elevation at the thinnest corneal location afforded the single highest diagnostic performance (71% sensitivity and 85% specificity), whereas the best multivariate model combining intereye asymmetry in anterior and posterior keratometry, corneal thickness, and front and back elevation at the thinnest point provided 65% sensitivity and 97% specificity. Multivariate models upheld their performance in the validation dataset. Most (more than 90%) indeterminate patients, according to conventional Pentacam analysis, showed within-normal-range corneal asymmetry.

CONCLUSIONS

Healthy corneas are markedly symmetric irrespective of anisometropia, but corneal asymmetry analysis does not provide sufficient sensitivity to be used alone for detecting keratoconus. However, its remarkable specificity suggests that it could be used combined with conventional single cornea Pentacam analysis to reduce the false-positive rate or in dubious cases.

摘要

目的

评估Pentacam(德国韦茨拉尔奥culus Optikgeräte GmbH公司)指数中的双眼角膜不对称性,作为正常患者和圆锥角膜患者之间的一种诊断方法。

方法

一项回顾性观察病例系列研究,纳入177名健康者、44名不确定者以及121名根据Pentacam扩张检测指数分类的圆锥角膜患者,随机分为分析数据集和验证数据集。计算20个Scheimpflug断层扫描角膜描述符中的双眼不对称性,并进行比较以建立诊断模型。

结果

在健康对照者中,双眼不对称性与屈光参差无关,但在圆锥角膜患者中与较差眼的扩张程度相关。除相对厚度指数外,圆锥角膜患者在所有描述符中的双眼不对称性均显著更大。角膜最薄处的前表面高度的双眼不对称性具有最高的诊断性能(敏感性71%,特异性85%),而结合角膜前表面和后表面曲率、角膜厚度以及最薄点处的前后表面高度的双眼不对称性的最佳多变量模型的敏感性为65%,特异性为97%。多变量模型在验证数据集中保持了其性能。根据传统Pentacam分析,大多数(超过90%)不确定患者的角膜不对称性在正常范围内。

结论

无论有无屈光参差,健康角膜都具有明显的对称性,但角膜不对称性分析单独用于检测圆锥角膜时敏感性不足。然而,其显著的特异性表明,它可与传统的单角膜Pentacam分析联合使用以降低假阳性率,或用于可疑病例。