Suppr超能文献

牙科中的色差阈值

Color difference thresholds in dentistry.

作者信息

Paravina Rade D, Ghinea Razvan, Herrera Luis J, Bona Alvaro D, Igiel Christopher, Linninger Mercedes, Sakai Maiko, Takahashi Hidekazu, Tashkandi Esam, Perez Maria del Mar

机构信息

Department of Restorative Dentistry and Prosthodontics, School of Dentistry, University of Texas, Houston, TX, USA; Houston Center for Biomaterials and Biomimetics (HCBB), Houston, TX, USA.

出版信息

J Esthet Restor Dent. 2015 Mar-Apr;27 Suppl 1:S1-9. doi: 10.1111/jerd.12149. Epub 2015 Apr 17.

Abstract

PURPOSE

The aim of this prospective multicenter study was to determine 50:50% perceptibility threshold (PT) and 50:50% acceptability threshold (AT) of dental ceramic under simulated clinical settings.

MATERIALS AND METHODS

The spectral radiance of 63 monochromatic ceramic specimens was determined using a non-contact spectroradiometer. A total of 60 specimen pairs, divided into 3 sets of 20 specimen pairs (medium to light shades, medium to dark shades, and dark shades), were selected for psychophysical experiment. The coordinating center and seven research sites obtained the Institutional Review Board (IRB) approvals prior the beginning of the experiment. Each research site had 25 observers, divided into five groups of five observers: dentists-D, dental students-S, dental auxiliaries-A, dental technicians-T, and lay persons-L. There were 35 observers per group (five observers per group at each site ×7 sites), for a total of 175 observers. Visual color comparisons were performed using a viewing booth. Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points. The 50:50% PT and 50:50% AT were determined in CIELAB and CIEDE2000. The t-test was used to evaluate the statistical significance in thresholds differences.

RESULTS

The CIELAB 50:50% PT was ΔEab  = 1.2, whereas 50:50% AT was ΔEab  = 2.7. Corresponding CIEDE2000 (ΔE00 ) values were 0.8 and 1.8, respectively. 50:50% PT by the observer group revealed differences among groups D, A, T, and L as compared with 50:50% PT for all observers. The 50:50% AT for all observers was statistically different than 50:50% AT in groups T and L.

CONCLUSION

A 50:50% perceptibility and ATs were significantly different. The same is true for differences between two color difference formulas ΔE00 /ΔEab . Observer groups and sites showed high level of statistical difference in all thresholds.

CLINICAL SIGNIFICANCE

Visual color difference thresholds can serve as a quality control tool to guide the selection of esthetic dental materials, evaluate clinical performance, and interpret visual and instrumental findings in clinical dentistry, dental research, and subsequent standardization. The importance of quality control in dentistry is reinforced by increased esthetic demands of patients and dental professionals.

摘要

目的

这项前瞻性多中心研究的目的是在模拟临床环境下确定牙科陶瓷的50:50%可察觉阈值(PT)和50:50%可接受阈值(AT)。

材料与方法

使用非接触式光谱辐射计测定63个单色陶瓷标本的光谱辐射率。总共60对标本,分为3组,每组20对标本(中浅色调、中深色调和深色调),用于心理物理学实验。协调中心和七个研究地点在实验开始前获得了机构审查委员会(IRB)的批准。每个研究地点有25名观察者,分为五组,每组五名观察者:牙医-D、牙科学生-S、牙科辅助人员-A、牙科技术人员-T和外行人-L。每组有35名观察者(每个地点每组五名观察者×7个地点),总共175名观察者。使用观察箱进行视觉颜色比较。采用高木-菅野-康(TSK)模糊逼近法拟合数据点。在CIELAB和CIEDE2000中确定50:50%的PT和50:50%的AT。采用t检验评估阈值差异的统计学意义。

结果

CIELAB 50:50%的PT为ΔEab = 1.2,而50:50%的AT为ΔEab = 2.7。相应的CIEDE2000(ΔE00)值分别为0.8和1.8。与所有观察者的50:50%PT相比,观察者组的50:50%PT显示出D、A、T和L组之间的差异。所有观察者的50:50%AT与T组和L组的50:50%AT在统计学上有差异。

结论

50:50%的可察觉性和可接受性阈值有显著差异。两种色差公式ΔE00/ΔEab之间的差异也是如此。观察者组和地点在所有阈值上均显示出高度的统计学差异。

临床意义

视觉色差阈值可作为一种质量控制工具,用于指导美学牙科材料的选择、评估临床性能以及解释临床牙科、牙科研究及后续标准化中的视觉和仪器检测结果。患者和牙科专业人员对美学要求的提高强化了牙科质量控制的重要性。