Suppr超能文献

支架-血栓相互作用及抽吸对机械取栓的影响:在循环模型中对不同支架取栓器的评估

Stent-thrombus interaction and the influence of aspiration on mechanical thrombectomy: evaluation of different stent retrievers in a circulation model.

作者信息

Madjidyar Jawid, Hermes Julian, Freitag-Wolf Sandra, Jansen Olav

机构信息

Department of Radiology and Neuroradiology, Hospital Schleswig-Holstein (UKSH), Arnold-Heller-Str. 3, House 41, 24105, Kiel, Schleswig-Holstein, Germany,

出版信息

Neuroradiology. 2015 Aug;57(8):791-7. doi: 10.1007/s00234-015-1526-4. Epub 2015 Apr 24.

Abstract

INTRODUCTION

Different devices and techniques are available for endovascular treatment of ischemic stroke. In this in vitro study, we examined the stent-thrombus interaction and the influence of additional aspiration on the efficiency of mechanical thrombectomy with established stent retrievers.

METHODS

Human blood thrombi were made in a Chandler loop. The thrombi were placed into the middle cerebral artery of a vascular silicon phantom. A programmable piston pump was used to acquire physiological flow in the model. Resistances were interposed to gain physiological pressure. The stent retrievers Trevo, Solitaire FR, Separator 3D, and Aperio were used to perform thrombectomy under direct visual control. For the additional aspiration, we used intermediate catheters.

RESULTS

Ten attempts per device were made with and without aspiration under standardized conditions, a total of n = 80. For all thrombectomy maneuvers, it was demonstrated that the thrombus was pushed by the stent struts against the vessel wall and was retracted along it. The stent-thrombus interaction was only superficial for all devices. Using additional distal aspiration, the amount of distal embolism and rate of embolism in new territories was significantly lower than without. Moreover, additional aspiration reduced the number of recanalization maneuvers and the recanalization time.

CONCLUSION

Distal aspiration with intermediate catheters increases the efficacy of mechanical thrombectomy with stent retrievers significantly. In contrary to earlier suggestions, the interaction between the thrombus and the stent retriever is only superficial, rather than an integration of the thrombus into the retriever. No significant differences between the proven devices could be shown in our model.

摘要

引言

缺血性脑卒中的血管内治疗有多种不同的设备和技术。在这项体外研究中,我们使用已有的取栓支架,研究了支架与血栓的相互作用以及额外抽吸对机械取栓效率的影响。

方法

在钱德勒环路中制备人体血栓。将血栓置于血管硅橡胶模型的大脑中动脉内。使用可编程活塞泵在模型中获取生理血流。通过设置阻力来获得生理压力。在直接视觉控制下,使用Trevo、Solitaire FR、Separator 3D和Aperio取栓支架进行取栓操作。对于额外的抽吸,我们使用中间导管。

结果

在标准化条件下,对每种设备分别进行了10次有抽吸和无抽吸的尝试,共n = 80次。对于所有取栓操作,结果表明血栓被支架撑条推向血管壁并沿血管壁回缩。所有设备的支架与血栓的相互作用均仅为表面性的。使用额外的远端抽吸时,远端栓塞量和新区域的栓塞率显著低于不使用时。此外,额外抽吸减少了再通操作的次数和再通时间。

结论

使用中间导管进行远端抽吸可显著提高取栓支架的机械取栓效果。与早期观点相反,血栓与取栓支架之间的相互作用仅为表面性的,而非血栓融入取栓支架。在我们的模型中,未显示出已证实的设备之间存在显著差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验