Akdemir M Orcun, Kirgiz Ahmet, Ayar Orhan, Kaldirim Havva, Mert Metin, Cabuk Kubra Serefoglu, Taskapili Muhittin
a Department of Ophthalmology , School of Medicine, Bulent Ecevit University , Zonguldak , Turkey and.
b Bagcilar Education and Research Hospital, Eye Clinic , Istanbul , Turkey.
Curr Eye Res. 2016;41(3):305-10. doi: 10.3109/02713683.2015.1030505. Epub 2015 May 14.
PURPOSE/AIM OF THE STUDY: The aim of this study is to investigate the effect of pseudoexfoliation (PEX) and PEX-induced dry eye on central corneal thickness (CCT).
This cross-sectional study consists of total 270 eyes of 135 patients (67 females, 68 males) in total. After excluding the PEX (-) 32 eyes with PEX in the other eye, totally 130 eyes in PEX (-) group and 108 eyes in the PEX (+) group were included in the study. The PEX (+) group was regrouped as PEX syndrome (80 eyes of 50 patients) and PEX glaucoma (28 eyes of 20 patients).
In the PEX (-) group, the mean Schirmer test result was 12 ± 4 mm (4-25 mm), in the PEX syndrome group 10 ± 4 mm (4-22 mm), in the PEX glaucoma group 9 ± 3 mm (4-15 mm). The difference among the PEX (-) group, the PEX syndrome and the PEX glaucoma groups was statistically significant (p < 0.001, p < 0.001, respectively). In the PEX (-) group, the mean tear break up time test result was 11 ± 2 s (5-16 s), in the PEX syndrome group 8 ± 3 (3-16 s), in the PEX glaucoma group 8 ± 3 s (5-15 s). Mean CCT result was 544 µm in the PEX (-), 521 µm in the PEX syndrome group and 533 µm in the PEX glaucoma group. The difference among the PEX (-) group, the PEX syndrome and the PEX glaucoma groups was significant (p < 0.001, p = 0.030, respectively). There was a significant (+) correlation between intraocular pressure and CCT in the eyes with PEX (r = 0.307, p = 0.001). However, there was no statistically significant correlation between CCT, Schirmer and tear break up time tests in the eyes with PEX.
PEX material can cause decrease in tear film secretion and disturb tear film stability. There is no effect of PEX-induced dry eye on CCT. Lower CCT values in the eyes with PEX material may be a result of decrease in corneal stromal cell density. Moreover, higher CCT values may be because of decreased endothelial cells in PEX glaucoma patients.
本研究旨在探讨假性剥脱(PEX)及PEX诱发的干眼对中央角膜厚度(CCT)的影响。
本横断面研究共纳入135例患者(67例女性,68例男性)的270只眼。排除另一只眼有PEX的PEX(-)32只眼后,研究共纳入PEX(-)组130只眼和PEX(+)组108只眼。PEX(+)组又分为PEX综合征(50例患者的80只眼)和PEX青光眼(20例患者的28只眼)。
PEX(-)组泪液分泌试验平均结果为12±4mm(4 - 25mm),PEX综合征组为10±4mm(4 - 22mm),PEX青光眼组为9±3mm(4 - 15mm)。PEX(-)组、PEX综合征组和PEX青光眼组之间的差异具有统计学意义(分别为p < 0.001,p < 0.001)。PEX(-)组泪膜破裂时间试验平均结果为11±2秒(5 - 16秒),PEX综合征组为8±3(3 - 16秒),PEX青光眼组为8±3秒(5 - 15秒)。PEX(-)组CCT平均结果为544μm,PEX综合征组为521μm,PEX青光眼组为533μm。PEX(-)组、PEX综合征组和PEX青光眼组之间的差异具有统计学意义(分别为p < 0.001,p = 0.030)。PEX患者眼内压与CCT之间存在显著正相关(r = 0.307,p = 0.001)。然而,PEX患者眼中CCT、泪液分泌试验和泪膜破裂时间试验之间无统计学显著相关性。
PEX物质可导致泪膜分泌减少并扰乱泪膜稳定性。PEX诱发的干眼对CCT无影响。有PEX物质的眼CCT值较低可能是角膜基质细胞密度降低的结果。此外,PEX青光眼患者CCT值较高可能是由于内皮细胞减少。