Suppr超能文献

双侧植入及联合使用两种相似多焦点人工晶状体后的长期视觉功能和患者满意度

Long-term visual function and patient satisfaction after bilateral implantation and combination of two similar multifocal IOLs.

作者信息

Mastropasqua Rodolfo, Pedrotti Emilio, Passilongo Mattia, Parisi Graziella, Marchesoni Ivan, Marchini Giorgio

出版信息

J Refract Surg. 2015 May;31(5):308-14. doi: 10.3928/1081597X-20150423-04.

Abstract

PURPOSE

To evaluate the visual outcome, spectacle independence, and patient satisfaction after implantation of two Acrysof ReSTOR (Alcon Laboratories, Inc., Fort Worth, TX) intraocular lenses (IOLs) with different addition power or their combination in both eyes.

METHODS

One hundred twenty eyes of 60 patients with bilateral multifocal IOL implantation were divided into three groups of 20 consecutive patients each: the SV25T0 (the T0 group), the SN6AD1 (the D1 group), or a combination of both the SN6AD1 and SV25T0 (the combined group). Patients were observed 18 months postoperatively for visual acuity (40, 50, and 60 cm, and 4 m), defocus curves (range: +1.0 to -4.0 diopters), and contrast sensitivity. Quality of vision, patient satisfaction, and spectacle independence were evaluated by the National Eye Institute Refractive Error Quality of Life Instrument-42 questionnaire.

RESULTS

The D1 group achieved better results for near vision (P < .01), whereas the T0 group achieved better intermediate vision (P = .01). The combined group showed a wider range of spectacle independence at all distances evaluated (P < .05). The contrast sensitivity was similar within the groups. The incidence of glare was lower for the T0 group (P = .054). The combined group had better results in terms of expectation (P = .021) and activity limitation (P = .003).

CONCLUSION

Although the bilateral implantation of the same multifocal IOL can maximize the vision for near or intermediate distances, the combination of these IOLs in both eyes can increase the range of spectacle independence without compromising the contrast sensitivity and quality of vision.

摘要

目的

评估双眼植入两种不同附加屈光度的Acrysof ReSTOR(爱尔康实验室公司,沃思堡,德克萨斯州)人工晶状体(IOL)或其组合后的视觉效果、摆脱眼镜依赖情况和患者满意度。

方法

60例接受双眼多焦点IOL植入的患者的120只眼被连续分为三组,每组20例患者:SV25T0(T0组)、SN6AD1(D1组)或SN6AD1与SV25T0的组合(联合组)。术后18个月观察患者的视力(40、50和60厘米以及4米处)、散焦曲线(范围:+1.0至-4.0屈光度)和对比敏感度。通过美国国立眼科研究所屈光不正生活质量量表-42问卷评估视觉质量、患者满意度和摆脱眼镜依赖情况。

结果

D1组在近视力方面取得了更好的结果(P <.01),而T0组在中距离视力方面取得了更好的结果(P =.01)。联合组在所有评估距离下都表现出更广泛的摆脱眼镜依赖范围(P <.05)。各组内的对比敏感度相似。T0组的眩光发生率较低(P =.054)。联合组在期望(P =.021)和活动受限(P =.003)方面取得了更好的结果。

结论

虽然双侧植入相同的多焦点IOL可以使近或中距离视力最大化,但双眼植入这些IOL的组合可以增加摆脱眼镜依赖的范围,而不会损害对比敏感度和视觉质量。