Kretz Florian T A, Tandogan Tamer, Khoramnia Ramin, Auffarth Gerd U
International Vision Correction Research Centre & David J Apple International Laboratory for Ocular Pathology of the Department of Ophthalmology, University Hospital Heidelberg, Heidelberg 69120, Germany ; International Vision Correction Research Network (IVCRC.net), Heidelberg 69120, Germany ; Augenklinik Ahaus-Raesfeld-Rheine, Gerl Group, Ahaus 48683, Germany.
International Vision Correction Research Centre & David J Apple International Laboratory for Ocular Pathology of the Department of Ophthalmology, University Hospital Heidelberg, Heidelberg 69120, Germany ; International Vision Correction Research Network (IVCRC.net), Heidelberg 69120, Germany.
Int J Ophthalmol. 2015 Aug 18;8(4):736-41. doi: 10.3980/j.issn.2222-3959.2015.04.17. eCollection 2015.
To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting, monofocal intraocular lens (IOL).
Twenty-one patients (34 eyes) aged 50 to 83y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL (Tecnis ZCB00, Abbott Medical Optics). Three months after surgery they were examined for uncorrected (UDVA) and corrected distance visual acuity (CDVA), contrast sensitivity (CS) under photopic and mesopic conditions with and without glare source, ocular high order aberrations (HOA, Zywave II) and retinal straylight (C-Quant).
Postoperatively, patients achieved a postoperative CDVA of 0.0 logMAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27 (primary coma components) and -0.04±0.16 (spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed (P≥0.28).
The implantation of an aspherical aberration correcting monofocal IOL after cataract surgery resulted in very low residual higher order aberration (HOA) and normal straylight.
评估植入非球面、像差校正单焦点人工晶状体(IOL)后高阶像差和杂散光感知方面的视觉质量。
21例年龄在50至83岁之间的患者(34只眼)接受了白内障手术并植入了非球面、像差校正IOL(Tecnis ZCB00,雅培医疗光学公司)。术后三个月,对他们进行了未矫正远视力(UDVA)和矫正远视力(CDVA)、明视和暗视条件下有无眩光光源时的对比敏感度(CS)、眼高阶像差(HOA,Zywave II)以及视网膜杂散光(C-Quant)检查。
术后,97.1%的眼睛术后CDVA达到0.0 logMAR或更好。高阶像差的平均值为+0.02±0.27(初级彗差分量)和-0.04±0.16(球差项)。C-Quant的杂散光值为1.35±0.44 log,在年龄匹配的有晶状体患者的正常范围内。在观察的患者组中,暗视和明视条件下有无眩光时的CS测量均未显示出任何统计学意义(P≥0.28)。
白内障手术后植入非球面像差校正单焦点IOL导致非常低的残余高阶像差(HOA)和正常的杂散光。