Suppr超能文献

植入非球面和球面人工晶状体的眼睛的球差和对比敏感度:一项比较研究。

Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study.

作者信息

Tzelikis Patrick F, Akaishi Leonardo, Trindade Fernando C, Boteon Joel E

机构信息

Brasília Ophthalmologic Hospital, HOB, Brasília, Brazil.

出版信息

Am J Ophthalmol. 2008 May;145(5):827-33. doi: 10.1016/j.ajo.2007.12.023. Epub 2008 Mar 4.

Abstract

PURPOSE

To determine whether implantation of an intraocular lens (IOL) with a modified anterior aspheric surface results in reduced spherical aberration and improved contrast sensitivity after cataract surgery.

DESIGN

Prospective, comparative, interventional case series.

METHODS

In an intraindividual randomized prospective study of 25 patients with bilateral cataract, an IOL with a modified anterior surface (Tecnis Z9001; Advanced Medical Optics, Santa Ana, California, USA; group 1) was compared with biconvex lens with spherical surfaces (ClariFlex; Advanced Medical Optics; group 2). Ocular aberrations for a 5.0-mm pupil and 6.0-mm pupil were measured with Hartmann-Shack aberrometer. Quality of vision was measured by visual acuity and contrast sensitivity under mesopic and photopic conditions. All patients were followed up for three months.

RESULTS

No statistically significant difference in postoperative uncorrected and best-corrected distance vision acuity after a follow-up of three months existed between the groups. Postoperative contrast sensitivity testing revealed significant differences between the groups under photopic and mesopic conditions. These differences reached statistical significance under photopic conditions at three spatial frequencies and under mesopic conditions at all spatial frequencies. When analyzing higher-order aberrations, the difference between the groups was statistically significant at the 5.00-mm and 6.00-mm pupil diameters, with the group 1 inducing less higher-order aberration and also less spherical aberration compared with group 2.

CONCLUSIONS

Results show the Tecnis Z9001 IOL with a modified anterior aspheric surface induced significantly less higher-order aberration and spherical aberration compared with the ClariFlex IOL. Contrast sensitivity revealed better values under photopic and mesopic conditions with the Tecnis Z9001 IOL.

摘要

目的

确定植入具有改良前非球面表面的人工晶状体(IOL)是否会在白内障手术后降低球差并提高对比敏感度。

设计

前瞻性、比较性、干预性病例系列研究。

方法

在一项针对25例双侧白内障患者的个体内随机前瞻性研究中,将具有改良前表面的IOL(Tecnis Z9001;美国加利福尼亚州圣安娜市先进医学光学公司;第1组)与具有球面的双凸透镜(ClariFlex;先进医学光学公司;第2组)进行比较。使用哈特曼-夏克像差仪测量5.0毫米瞳孔和6.0毫米瞳孔的眼像差。在中暗视觉和明视觉条件下,通过视力和对比敏感度测量视觉质量。所有患者均随访三个月。

结果

随访三个月后,两组之间术后未矫正和最佳矫正远视力 acuity 无统计学显著差异。术后对比敏感度测试显示,在明视觉和中暗视觉条件下,两组之间存在显著差异。这些差异在明视觉条件下的三个空间频率以及中暗视觉条件下的所有空间频率均达到统计学显著性。在分析高阶像差时,两组之间在5.00毫米和6.00毫米瞳孔直径时差异具有统计学显著性,与第2组相比,第1组诱导的高阶像差和球差也更少。

结论

结果表明,与ClariFlex IOL相比,具有改良前非球面表面的Tecnis Z9001 IOL诱导的高阶像差和球差明显更少。在明视觉和中暗视觉条件下,Tecnis Z9001 IOL的对比敏感度值更好。