文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Adaptive servo-ventilation therapy of central sleep apnoea and its effect on sleep quality.

作者信息

Hetzenecker Andrea, Roth Tatjana, Birner Christoph, Maier Lars S, Pfeifer Michael, Arzt Michael

机构信息

Department of Internal Medicine II, Cardiology and Pneumology, Centre for Sleep Medicine, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany.

Department of Pneumology, Donaustauf Hospital, Donaustauf, Germany.

出版信息

Clin Res Cardiol. 2016 Mar;105(3):189-95. doi: 10.1007/s00392-015-0904-6. Epub 2015 Sep 5.


DOI:10.1007/s00392-015-0904-6
PMID:26342603
Abstract

OBJECTIVES: Poor sleep quality is common in patients with chronic heart failure (CHF). This study tested the hypothesis that adaptive servo-ventilation (ASV) therapy in CHF patients whose central sleep apnoea (CSA) was not suppressed by continuous positive airway pressure (CPAP) (CPAP-non-responders) would improve sleep quality compared to CPAP-responders receiving ongoing CPAP therapy. METHODS: Eighty-two patients with CHF (65 ± 9 years, left ventricular ejection fraction 35 ± 16 %) and CSA [apnoea-hypopnoea index (AHI) ≥15/h] were retrospectively studied. Within an average of 47 days, patients were reevaluated on CPAP therapy and stratified according to their suppression of CSA: 34 were CPAP-non-responders switched to ASV therapy the following day and 48 were CPAP-responders who continued on CPAP therapy. Polysomnographic parameters were assessed in the diagnostic night and on the last night of PAP therapy (CPAP or ASV) before the patient was discharged with the final pressure settings. RESULTS: Compared with the CPAP group, the ASV group had significantly greater reductions from baseline in AHI (-37 ± 15/h vs -28 ± 18/h, p = 0.02), arousal index (-12.7 ± 13.6/h vs -6.8 ± 12.5/h, p = 0.04) and sleep stage N1 (-9 ± 14 % vs -2 ± 12 %, p = 0.03). In addition, the ASV group gained significantly more rapid eye movement (REM) sleep compared with the CPAP group (+5 ± 9 % vs +1 ± 9 %, p = 0.02). CONCLUSIONS: CPAP therapy is effective in reducing AHI in a significant proportion of CHF patients with reduced ejection fraction and CSA. Treatment of CSA with ASV in CHF patients reduces sleep fragmentation and improves sleep structure to a significantly greater extent than changes seen in responders to CPAP therapy.

摘要

相似文献

[1]
Adaptive servo-ventilation therapy of central sleep apnoea and its effect on sleep quality.

Clin Res Cardiol. 2016-3

[2]
Adaptive servo-ventilation and sleep quality in treatment emergent central sleep apnea and central sleep apnea in patients with heart disease and preserved ejection fraction.

Clin Res Cardiol. 2018-1-25

[3]
Adaptive servo-ventilation in cardiac function and neurohormonal status in patients with heart failure and central sleep apnea nonresponsive to continuous positive airway pressure.

JACC Heart Fail. 2013-2-4

[4]
Non-invasive positive pressure ventilation for central sleep apnoea in adults.

Cochrane Database Syst Rev. 2022-10-24

[5]
Adaptive servo-ventilation therapy does not favourably alter sympatho-vagal balance in sleeping patients with systolic heart failure and central apnoeas: Preliminary data.

Int J Cardiol. 2020-9-15

[6]
Effect of flow-triggered adaptive servo-ventilation compared with continuous positive airway pressure in patients with chronic heart failure with coexisting obstructive sleep apnea and Cheyne-Stokes respiration.

Circ Heart Fail. 2009-11-20

[7]
Effect of Treatment of Central Sleep Apnea/Cheyne-Stokes Respiration on Left Ventricular Ejection Fraction in Heart Failure: A Network Meta-Analysis.

J Clin Sleep Med. 2019-12-15

[8]
Suppression of central sleep apnea by continuous positive airway pressure and transplant-free survival in heart failure: a post hoc analysis of the Canadian Continuous Positive Airway Pressure for Patients with Central Sleep Apnea and Heart Failure Trial (CANPAP).

Circulation. 2007-6-26

[9]
The effect of continuous positive airway pressure on heart rate variability during the night in patients with chronic heart failure and central sleep apnoea.

Clin Exp Pharmacol Physiol. 2016-12

[10]
Clinical impact of adaptive servoventilation compared to other ventilatory modes in patients with treatment-emergent sleep apnea, central sleep apnea and Cheyne-Stokes respiration.

Rev Port Pneumol (2006). 2015

引用本文的文献

[1]
Non-invasive positive pressure ventilation for central sleep apnoea in adults.

Cochrane Database Syst Rev. 2022-10-24

[2]
Effects of hyperventilation length on muscle sympathetic nerve activity in healthy humans simulating periodic breathing.

Front Physiol. 2022-9-5

[3]
Effect of adaptive servo ventilation on central sleep apnea and sleep structure in systolic heart failure patients: polysomnography data from the SERVE-HF major sub study.

J Sleep Res. 2022-12

[4]
Adaptive servo-ventilation in patients with chronic heart failure and sleep disordered breathing: predictors of usage.

Sleep Breath. 2021-6

[5]
Positive airway pressure therapy for the treatment of central sleep apnoea associated with heart failure.

Cochrane Database Syst Rev. 2019-12-4

[6]
Long-term effects of device-guided slow breathing in stable heart failure patients with reduced ejection fraction.

Clin Res Cardiol. 2018-6-25

[7]
Sex Differences in the Prevalence and Modulators of Sleep-Disordered Breathing in Outpatients with Type 2 Diabetes.

J Diabetes Res. 2018-4-1

[8]
[Comorbidities of heart failure: sleep apnea].

Internist (Berl). 2018-5

[9]
Adaptive servo-ventilation and sleep quality in treatment emergent central sleep apnea and central sleep apnea in patients with heart disease and preserved ejection fraction.

Clin Res Cardiol. 2018-1-25

[10]
Adaptive servoventilation in clinical practice: beyond SERVE-HF?

ERJ Open Res. 2017-10-23

本文引用的文献

[1]
Central sleep apnoea in congestive heart failure.

Lancet Respir Med. 2015-7

[2]
Prognostic impact of sleep duration and sleep efficiency on mortality in patients with chronic heart failure.

Sleep Med. 2013-4-28

[3]
Rationale and design of the SERVE-HF study: treatment of sleep-disordered breathing with predominant central sleep apnoea with adaptive servo-ventilation in patients with chronic heart failure.

Eur J Heart Fail. 2013-3-27

[4]
Adaptive servo-ventilation therapy improves cardiac sympathetic nerve activity in patients with heart failure.

Eur J Heart Fail. 2013-3-15

[5]
Auto-servoventilation in heart failure with sleep apnoea: a randomised controlled trial.

Eur Respir J. 2012-12-6

[6]
Long-term auto-servoventilation or constant positive pressure in heart failure and coexisting central with obstructive sleep apnea.

Chest. 2012-8

[7]
The treatment of central sleep apnea syndromes in adults: practice parameters with an evidence-based literature review and meta-analyses.

Sleep. 2012-1-1

[8]
Effect of oxygen versus adaptive pressure support servo-ventilation in patients with central sleep apnoea-Cheyne Stokes respiration and congestive heart failure.

Intern Med J. 2012-10

[9]
Relation of natriuretic peptide concentrations to central sleep apnea in patients with heart failure.

Chest. 2011-6-2

[10]
Prognostic impact of sleep disordered breathing and its treatment in heart failure: an observational study.

Eur J Heart Fail. 2010-10-20

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索