Fatseas George, Stapleton Fiona, Versace Patrick
School of Optometry and Vision Science, Faculty of Science, UNSW Australia, Kensington, New South Wales, Australia.
Vision Eye Institute, Bondi Junction, New South Wales, Australia.
PLoS One. 2017 Feb 2;12(2):e0170559. doi: 10.1371/journal.pone.0170559. eCollection 2017.
To determine the effect of hyperopic laser in situ keratomileusis (H-LASIK) on corneal integrity, by investigating relationships between proportionate corneal tissue ablated and refractive outcomes at 3 months.
18 eyes of 18 subjects treated with H-LASIK by Technolas 217c Excimer Laser were included in the study. Orbscan II Topography System was used to determine corneal volume and pachymetry 3mm temporally (3T). The volume of corneal tissue ablated was determined from the laser nomogram. Univariate associations between age, treatment, corneal volume, overall proportion of tissue removed, proportion of tissue removed at 3T, residual bed thickness at 3T and refractive outcomes 3 months post-LASIK were examined and independent factors associated with refractive outcomes determined using linear regression models.
At 3 months post-LASIK, the mean difference to expected refractive outcome was -0.20 ± 0.64 (Range -2.00 to +1.00). In univariate analysis, difference to expected refractive outcome was associated with proportion of tissue removed at 3T (P<0.01, r = -0.605) and total number of pulses (P< 0.05, r = -0.574). In multivariable analysis, difference to expected refractive outcome was associated with the proportion of tissue removed at 3T only.
Subjects undergoing H-LASIK, may present as either over or under-corrected at 3 months. The proportion of tissue removed at 3T was the single significant determinant of this outcome, suggesting unexpected biomechanical alterations resulting in corneal steepening. Future hyperopic LASIK procedures could consider proportionate volume of corneal tissue removed at 3T in addition to laser nomograms to achieve improved refractive outcomes.
通过研究3个月时角膜组织切除比例与屈光结果之间的关系,确定远视性准分子原位角膜磨镶术(H-LASIK)对角膜完整性的影响。
本研究纳入了18名接受Technolas 217c准分子激光H-LASIK治疗的受试者的18只眼。使用Orbscan II地形系统测定颞侧3mm处(3T)的角膜体积和角膜厚度。根据激光列线图确定切除的角膜组织体积。检查年龄、治疗、角膜体积、组织切除的总体比例、3T处组织切除比例、3T处残余床厚度与LASIK术后3个月屈光结果之间的单变量关联,并使用线性回归模型确定与屈光结果相关的独立因素。
LASIK术后3个月,与预期屈光结果的平均差值为-0.20±0.64(范围-2.00至+1.00)。在单变量分析中,与预期屈光结果的差值与3T处组织切除比例(P<0.01,r = -0.605)和脉冲总数(P<0.05,r = -0.574)相关。在多变量分析中,与预期屈光结果的差值仅与3T处组织切除比例相关。
接受H-LASIK治疗的受试者在3个月时可能出现矫正过度或不足。3T处组织切除比例是该结果的唯一重要决定因素,提示意外的生物力学改变导致角膜变陡。未来的远视性LASIK手术除了考虑激光列线图外,还可考虑3T处切除的角膜组织体积,以获得更好的屈光结果。