Suppr超能文献

肾CT血管造影中的造影剂注射及图像采集参数:放射科医生需要了解的内容

Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

作者信息

Saade Charbel, Deeb Ibrahim Alsheikh, Mohamad Maha, Al-Mohiy Hussain, El-Merhi Fadi

机构信息

Department of Radiology, American University of Beirut, Beirut, Lebanon.

出版信息

Diagn Interv Radiol. 2016 Mar-Apr;22(2):116-24. doi: 10.5152/dir.2015.15219.

Abstract

Over the last decade, exponential advances in computed tomography (CT) technology have resulted in improved spatial and temporal resolution. Faster image acquisition enabled renal CT angiography to become a viable and effective noninvasive alternative in diagnosing renal vascular pathologies. However, with these advances, new challenges in contrast media administration have emerged. Poor synchronization between scanner and contrast media administration have reduced the consistency in image quality with poor spatial and contrast resolution. Comprehensive understanding of contrast media dynamics is essential in the design and implementation of contrast administration and image acquisition protocols. This review includes an overview of the parameters affecting renal artery opacification and current protocol strategies to achieve optimal image quality during renal CT angiography with iodinated contrast media, with current safety issues highlighted.

摘要

在过去十年中,计算机断层扫描(CT)技术呈指数级进步,带来了空间和时间分辨率的提升。更快的图像采集使得肾脏CT血管造影成为诊断肾血管病变可行且有效的非侵入性替代方法。然而,随着这些进展,对比剂给药方面出现了新的挑战。扫描仪与对比剂给药之间的同步不佳降低了图像质量的一致性,导致空间和对比分辨率较差。全面了解对比剂动力学对于对比剂给药和图像采集方案的设计与实施至关重要。本综述概述了影响肾动脉强化的参数以及在使用碘化对比剂进行肾脏CT血管造影时实现最佳图像质量的当前方案策略,并突出了当前的安全问题。

相似文献

3
Cardiothoracic CT angiography: current contrast medium delivery strategies.
AJR Am J Roentgenol. 2011 Mar;196(3):W260-72. doi: 10.2214/AJR.10.5814.
6
An augmented patient-specific approach to administration of contrast agent for CT renal angiography.
Int Braz J Urol. 2019 Sep-Oct;45(5):1022-1032. doi: 10.1590/S1677-5538.IBJU.2018.0366.
7
Carotid and cerebral CT angiography using low volume of iodinated contrast material and low tube voltage.
Diagn Interv Imaging. 2016 Nov;97(11):1173-1179. doi: 10.1016/j.diii.2016.06.005. Epub 2016 Jul 12.
8
Dynamic CTA in Native Kidneys Using a Multiphase CT Protocol-Potential of Significant Reduction of Contrast Medium.
Acad Radiol. 2018 Jul;25(7):842-849. doi: 10.1016/j.acra.2017.11.012. Epub 2018 Mar 12.
9
State of the art of coronary computed tomography angiography.
Radiography (Lond). 2020 May;26(2):174-182. doi: 10.1016/j.radi.2019.10.001. Epub 2019 Nov 6.
10
Use of computed tomography renal angiography for screening feline renal transplant donors.
Vet Radiol Ultrasound. 2003 Nov-Dec;44(6):636-41. doi: 10.1111/j.1740-8261.2003.tb00522.x.

引用本文的文献

2
Segmentation of renal vessels on non-enhanced CT images using deep learning models.
Abdom Radiol (NY). 2025 May 13. doi: 10.1007/s00261-025-04984-y.
5
Depiction rate of feeding arteries of renal cell carcinoma on four-dimensional computed tomography angiography.
Jpn J Radiol. 2024 Jun;42(6):648-655. doi: 10.1007/s11604-024-01538-y. Epub 2024 Feb 23.
6
Optimising image quality in intravenous cerebral cone beam computed tomography.
J Med Radiat Sci. 2024 Mar;71(1):26-34. doi: 10.1002/jmrs.735. Epub 2023 Oct 17.
7
The effectiveness of post-processing head and neck CT angiography using contrast enhancement boost technique.
PLoS One. 2023 Apr 20;18(4):e0284793. doi: 10.1371/journal.pone.0284793. eCollection 2023.

本文引用的文献

1
Contrast Medium Administration and Parameters Affecting Bolus Geometry in Multidetector Computed Tomography Angiography: An Overview.
J Med Imaging Radiat Sci. 2011 Sep;42(3):113-117. doi: 10.1016/j.jmir.2011.05.002. Epub 2011 Jul 27.
2
Clinical Implementation of the New MEDRAD XDS Contrast Extravasation Detector for Multidetector Computed Tomography.
J Med Imaging Radiat Sci. 2011 Dec;42(4):179-182. doi: 10.1016/j.jmir.2011.05.003. Epub 2011 Jun 25.
4
5
Intravenous Iodinated Contrast Agents Amplify DNA Radiation Damage at CT.
Radiology. 2015 Jun;275(3):692-7. doi: 10.1148/radiol.14132478. Epub 2015 Feb 4.
6
Optimizing contrast media injection protocols in state-of-the art computed tomographic angiography.
Invest Radiol. 2015 Mar;50(3):161-7. doi: 10.1097/RLI.0000000000000119.
7
MDCT Venography Evaluation of a Rare Collateral Vein Draining from the Left Subclavian Vein to the Great Cardiac Vein.
J Clin Imaging Sci. 2014 Oct 27;4:58. doi: 10.4103/2156-7514.143425. eCollection 2014.
9
Prophylaxis of contrast-induced nephrotoxicity.
Biomed Res Int. 2014;2014:308316. doi: 10.1155/2014/308316. Epub 2014 Apr 10.