Cochener Béatrice, Patel Sunni R, Galliot Florence
J Refract Surg. 2016 Feb;32(2):104-9. doi: 10.3928/1081597X-20151222-01.
To evaluate whether correlations exist between objective and subjective measures of vision quality as a consequence of cataract and whether this may qualify the Objective Scatter Index as a supplementary means of cataract assessment.
A prospective multicenter, cross-sectional study was conducted in 10 centers across France in patients undergoing cataract extraction surgery (lens opacity evaluated with the Lens Opacities Classification System III). A quality of life assessment using the Visual Function Index-14 (VF-14) (14 questions scored from 0 to 4) and measurement of visual acuity and evaluation of the Objective Scatter Index (HD Analyzer, Visiometrics SL, Terrassa, Spain) to assess the alteration of light scatter were used as measures in the study.
The study included 1,768 eyes of 1,768 patients (mean age: 72.5 years; range: 28 to 93 years). The average OSI score was 4.97 ± 3.13 (range: 0.4 to 20.5). There was good correlation between visual acuity and OSI (r = -0.47, P < .001) and between OSI and VF-14 (r = -0.11, P < .001).
The results presented in this study confirm that the Objective Scatter Index has sufficient correlations with visual acuity and VF-14 to supplement existing cataract diagnosis in a large population encompassing a broad spectrum of cataract presentations.
评估白内障导致的视力质量客观测量指标与主观测量指标之间是否存在相关性,以及这是否使客观散射指数有资格作为白内障评估的补充手段。
在法国的10个中心对接受白内障摘除手术的患者进行了一项前瞻性多中心横断面研究(使用晶状体混浊分类系统III评估晶状体混浊情况)。研究采用视觉功能指数-14(VF-14)(14个问题,评分从0到4)进行生活质量评估,测量视力,并使用客观散射指数(HD分析仪,Visiometrics SL,西班牙特拉萨)评估光散射的改变作为研究指标。
该研究纳入了1768例患者的1768只眼(平均年龄:72.5岁;范围:28至93岁)。平均客观散射指数(OSI)评分为4.97±3.13(范围:0.4至20.5)。视力与OSI之间存在良好相关性(r = -0.47,P <.001),OSI与VF-14之间也存在良好相关性(r = -0.11,P <.001)。
本研究结果证实,客观散射指数与视力和VF-14有足够的相关性,可在涵盖广泛白内障表现的大量人群中补充现有的白内障诊断。