Alharbi Muaddi, Bauman Adrian, Neubeck Lis, Gallagher Robyn
Charles Perkins Centre, University of Sydney, Australia
Charles Perkins Centre, University of Sydney, Australia.
Eur J Prev Cardiol. 2016 Sep;23(14):1476-85. doi: 10.1177/2047487316634883. Epub 2016 Feb 23.
Accurate physical activity monitoring is important for cardiac patients. Novel activity monitoring devices may enable precise measurement of physical activity. This study aimed to validate Fitbit-Flex against Actigraph accelerometer for monitoring physical activity.
A validation study with a comparative design.
Cardiac patients and family members participating in community-based exercise programs wore Fitbit-Flex and Actigraph simultaneously over four days to monitor daily step counts and minutes of moderate to vigorous physical activity (MVPA).
Participants (N = 48) comprised 52.1% males, with a mean age of 65.6 ± 6.9 years and 58.9% had a cardiac diagnosis. Fitbit-Flex and Actigraph were significantly correlated in males, females, total participants and cardiac patients for step counts (r = .96; r = .95; r = .95; r = .95), though less so for MVPA (r = .81; r = .65, r = .74; r = .71). As step counts increased the differences between Fitbit-Flex and Actigraph also increased. Fitbit-Flex over-estimated step counts in females (556 steps/day), males (1462 steps/day) and total participants (1038 steps/day) as well as for minutes of MVPA in females (4 min/day), males (15 min/day) and total participants (10 min/day). Fitbit-Flex had high sensitivity and specificity in classifying participants who achieved the recommended physical activity guidelines.
Fitbit-Flex is accurate in assessing attainment of physical activity guideline recommendations and is useful for monitoring physical activity in cardiac patients. The device does, however, slightly over-estimate step counts and MVPA.
准确监测身体活动对心脏病患者很重要。新型活动监测设备可能有助于精确测量身体活动。本研究旨在验证Fitbit-Flex与Actigraph加速度计在监测身体活动方面的有效性。
一项采用对比设计的验证研究。
参与社区锻炼项目的心脏病患者及其家庭成员在四天内同时佩戴Fitbit-Flex和Actigraph,以监测每日步数和中度至剧烈身体活动(MVPA)的分钟数。
参与者(N = 48)中男性占52.1%,平均年龄为65.6±6.9岁,58.9%患有心脏病。Fitbit-Flex和Actigraph在男性、女性、所有参与者以及心脏病患者的步数方面显著相关(r = 0.96;r = 0.95;r = 0.95;r = 0.95),不过在MVPA方面相关性较低(r = 0.81;r = 0.65;r = 0.74;r = 0.71)。随着步数增加,Fitbit-Flex与Actigraph之间的差异也增大。Fitbit-Flex在女性(每天高估556步)、男性(每天高估1462步)和所有参与者(每天高估1038步)中高估了步数,在女性(每天高估4分钟)、男性(每天高估15分钟)和所有参与者(每天高估10分钟)中高估了MVPA的分钟数。Fitbit-Flex在对达到推荐身体活动指南的参与者进行分类时具有较高的敏感性和特异性。
Fitbit-Flex在评估身体活动指南建议的达成情况方面是准确的,并且对于监测心脏病患者的身体活动很有用。然而,该设备确实略微高估了步数和MVPA。