Suppr超能文献

白内障对使用RETeval™系统记录的闪烁视网膜电图的影响:新型免散瞳视网膜电图设备

Effects of cataracts on flicker electroretinograms recorded with RETeval™ system: new mydriasis-free ERG device.

作者信息

Miura Gen, Nakamura Yosuke, Sato Eiju, Yamamoto Shuichi

机构信息

Department of Ophthalmology and Visual Science, Chiba University Graduate School of Medicine, Inohana 1-8-1, Chuo-ku, Chiba, 260-8670, Japan.

出版信息

BMC Ophthalmol. 2016 Mar 5;16:22. doi: 10.1186/s12886-016-0200-x.

Abstract

BACKGROUND

The purpose of this study was to evaluate the effects of cataracts on the flicker electroretinograms (ERGs) recorded with the RETeval™ system under mydriatic-free conditions.

METHODS

This was a retrospective study of 82 eyes of 60 patients with cataracts and 52 eyes of 38 patients who were pseudophakic. Flicker ERGs were recorded with the RETeval™ system (LKC Technologies, Gaithersburg, MD) under mydriatic-free condition with skin electrodes. Flicker ERGs were elicited by white light delivered at a frequency of 28.3 Hz and intensity of 8 Td-s. The implicit times and amplitudes of the ERGs recorded from the Grade 2 cataract, Grade 3 cataract, and pseudophakic groups were compared.

RESULTS

The mean amplitude was significantly smaller in both cataract groups than the pseudophakic group (Grade 2 cataract vs pseudophakic group, P < 0.0001; Grade 3 cataract vs pseudophakic group, P < 0.0001; Grade 2 cataract vs Grade 3 cataract, P = 0.027). The mean implicit times was significantly longer in both cataract groups than the pseudophakic group (Grade 2 cataract vs pseudophakic group, P = 0.046; Grade 3 cataract vs pseudophakic group, P = 0.0004; Grade 2 cataract vs Grade 3 cataract, P = 0.0084).

CONCLUSIONS

The results indicate that the presence of Grade 2 or more cataracts will affect both the amplitude and the implicit time of the flicker ERGs. The presence of cataracts should be taken into consideration when interpreting the flicker ERG recorded with RETeval™.

摘要

背景

本研究的目的是评估在不散瞳的情况下,白内障对使用RETeval™系统记录的闪烁视网膜电图(ERG)的影响。

方法

这是一项对60例白内障患者的82只眼和38例人工晶状体植入患者的52只眼进行的回顾性研究。在不散瞳的情况下,使用皮肤电极通过RETeval™系统(LKC Technologies,盖瑟斯堡,马里兰州)记录闪烁ERG。闪烁ERG由频率为28.3 Hz、强度为8 Td-s的白光诱发。比较2级白内障组、3级白内障组和人工晶状体植入组记录的ERG的潜伏时间和振幅。

结果

两个白内障组的平均振幅均显著低于人工晶状体植入组(2级白内障组与人工晶状体植入组比较,P < 0.0001;3级白内障组与人工晶状体植入组比较,P < 0.0001;2级白内障组与3级白内障组比较,P = 0.027)。两个白内障组的平均潜伏时间均显著长于人工晶状体植入组(2级白内障组与人工晶状体植入组比较,P = 0.046;3级白内障组与人工晶状体植入组比较,P = 0.0004;2级白内障组与3级白内障组比较,P = 0.0084)。

结论

结果表明,2级及以上白内障的存在会影响闪烁ERG的振幅和潜伏时间。在解释使用RETeval™记录的闪烁ERG时,应考虑白内障的存在。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f352/4779227/94ed97c7956f/12886_2016_200_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验