Suppr超能文献

使用光学相干断层扫描技术测量尼日利亚北部正常成年人的视网膜神经纤维层厚度

Retinal nerve fiber layer thickness measurements of normal Northern Nigerian adults using optical coherence tomography.

作者信息

Sani Rabi Yahaya, Abdu Lawal, Pam Victoria

机构信息

Department of Ophthalmology, Faculty of Clinical Sciences, College of Health Sciences, Bayero University, Kano, Nigeria.

出版信息

Ann Afr Med. 2016 Apr-Jun;15(2):52-7. doi: 10.4103/1596-3519.172557.

Abstract

OBJECTIVE

To assess retinal nerve fiber layer (RNFL) thickness measurements of normal Northern Nigerian adults using optical coherence tomography (OCT).

SUBJECTS AND METHODS

The OCT procedure was carried out with the Carl Zeiss Stratus OCT Model 3000 software version 4.0 (Carl Zeiss Meditec AG, Jena, Germany). The fast RNFL scan protocol was used to obtain RNFL thickness measurements. Student's t-test was used to compare mean RNFL thickness values. P ≤ 0.05 was considered as statistically significant. Average RNFL thickness was correlated with age.

RESULTS

Two hundred and twenty eyes of 110 subjects aged 18-51 years were examined. The average RNFL thickness was 104.17 ± 10.71 μm. The mean values for the RNFL thickness were 129.15 ± 16.87 μm, 135.34 ± 20.40 μm, 85.10 ± 23.60 μm, and 67.19 ± 13.27 μm for the inferior, superior, nasal, and temporal quadrants, respectively. A statistically significant difference was found between males and females for the mean RNFL thickness (t = 3.30, P = 0.001) and for the mean superior and inferior RNFL thickness. There was a statistically significant difference between right and left eyes (t = 3.73, P = 0.001) for the mean RNFL thickness. A negative correlation was found between RNFL thickness and age (r = -0.313, P = 0.002).

CONCLUSION

Normal RNFL thickness measurements in healthy Nigerian adults are presented. The RNFL was found to be thicker in females and in right eyes. The values were comparable to those of the Indian population but higher than some Caucasian values.

摘要

目的

使用光学相干断层扫描(OCT)评估尼日利亚北部正常成年人的视网膜神经纤维层(RNFL)厚度测量值。

对象与方法

使用卡尔·蔡司Stratus OCT 3000型软件版本4.0(卡尔·蔡司医疗技术股份公司,德国耶拿)进行OCT检查。采用快速RNFL扫描协议获取RNFL厚度测量值。使用学生t检验比较平均RNFL厚度值。P≤0.05被认为具有统计学意义。平均RNFL厚度与年龄相关。

结果

对110名年龄在18 - 51岁的受试者的220只眼睛进行了检查。平均RNFL厚度为104.17±10.71μm。RNFL厚度的平均值在下方象限为129.15±16.87μm,上方象限为135.34±20.40μm,鼻侧象限为85.10±23.60μm,颞侧象限为67.19±13.27μm。男性和女性之间的平均RNFL厚度(t = 3.30,P = 0.001)以及上方和下方RNFL平均厚度存在统计学显著差异。左右眼之间的平均RNFL厚度存在统计学显著差异(t = 3.73,P = 0.001)。RNFL厚度与年龄之间存在负相关(r = -0.313,P = 0.002)。

结论

给出了健康尼日利亚成年人的正常RNFL厚度测量值。发现女性和右眼的RNFL更厚。这些值与印度人群的值相当,但高于一些白种人的值。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/13a1/5402817/74c39562a198/AAM-15-52-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验