Abstract

PURPOSE

The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice.

MATERIALS AND METHODS

We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and compared with a 3D-CT based reconstruction model within the same radiographic coronal plane.

RESULTS

The mean difference between the radiographic and the 3D-CT measurements was - 1.4° ± 3.9° for inclination and 0.8°± 7.9° for anteversion with excellent correlation for inclination (r = 0.81, p < 0.001) and moderate correlation for anteversion (r = 0.65, p < 0.001). The intraclass correlation coefficient for measurements on radiographs ranged from 0.98 (95 %-CI: 0.98; 0.99) for the first observer to 0.94 (95 %-CI: 0.92; 0.96) for the second observer. The interrater reliability was 0.96 (95 %-CI: 0.93; 0.98) for inclination and 0.93 (95 %-CI: 0.85; 0.96) for anteversion.

CONCLUSION

The largest errors in measurements were associated with an extraordinary pelvic tilt. In order to get a valuable measurement for measuring cup position after THA on pelvic radiographs by this vector arithmetic method, there is a need for a correct postoperative ap view, with special regards to the pelvic tilt for the future.

KEY POINTS

• Measuring acetabular cup orientation on anteroposterior radiographs of the hip after THA is a helpful procedure in everyday clinical practice as a first-line imaging modality• CT remains the golden standard to accurately determine acetabular cup position.• Future measuring on radiographs for cup orientation after THA should account for integration of the pelvic tilt in order to maximize the measurement accuracy. Citation Format: • Craiovan B, Weber M, Worlicek M et al. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?. Fortschr Röntgenstr 2016; 188: 574 - 581.

摘要

目的

本前瞻性研究旨在验证一种用于测量全髋关节置换术(THA)后髋臼杯方向的向量算法方法,并验证其临床实用性。

材料与方法

我们由两名检查者使用向量算法方法在前后位骨盆X线片上对123例行初次非骨水泥型THA的患者的髋臼杯前倾角和倾斜角进行了两次测量,并与同一X线片冠状面内基于三维CT的重建模型进行比较。

结果

X线片测量值与三维CT测量值之间的平均差异为倾斜角-1.4°±3.9°,前倾角0.8°±7.9°,倾斜角相关性良好(r=0.81,p<0.001),前倾角相关性中等(r=0.65,p<0.001)。X线片测量的组内相关系数,第一位观察者为0.98(95%可信区间:0.98;0.99),第二位观察者为0.94(95%可信区间:0.92;0.96)。测量者间可靠性倾斜角为0.96(95%可信区间:0.93;0.98),前倾角为0.93(95%可信区间:0.85;0.96)。

结论

测量中的最大误差与异常的骨盆倾斜有关。为了通过这种向量算法方法在骨盆X线片上获得THA后测量髋臼杯位置的有价值测量结果,未来需要一张正确的术后前后位片,尤其要注意骨盆倾斜。

关键点

•在THA后的髋关节前后位X线片上测量髋臼杯方向是日常临床实践中作为一线成像方式的有用步骤•CT仍然是准确确定髋臼杯位置的金标准•未来在THA后X线片上测量髋臼杯方向应考虑骨盆倾斜的整合,以最大限度提高测量准确性。引用格式:•Craiovan B, Weber M, Worlicek M等。用向量算法放射学方法在全髋关节置换术后髋关节前后位X线片上测量髋臼杯方向。它在日常临床实践中有效且经过验证吗?。Fortschr Röntgenstr 2016; 188: 574 - 581。