[Measurement of acetabular cup inclination in anteroposterior pelvic radiogram : An indicator of quality after primary total hip arthroplasty?].

作者信息

Loitsch T, Freitag T, Leucht F, Reichel H, Bieger R

机构信息

RKU - Universitäts- und Rehabilitationskliniken Ulm GmbH, Oberer Eselsberg 45, 89081, Ulm, Deutschland.

出版信息

Orthopade. 2018 Dec;47(12):1003-1008. doi: 10.1007/s00132-018-3628-2.

Abstract

BACKGROUND AND OBJECTIVE

Acetabular cup orientation, consisting of pelvic positioning, version and inclination, can influence short-term and long-term results after total hip arthroplasty (THA). The radiographic measurement of acetabular cup inclination represents an indicator of quality for the EndoCert certification in Germany. The purpose of this study was to determine the intrarater and interrater reliability of radiographic measurements of acetabular cup inclination after THA.

MATERIAL AND METHODS

In this study four independent investigators with different levels of expertise retrospectively performed measurements on radiograms (anteroposterior pelvic radiogram) from 99 patients. The intraclass correlation coefficient (ICC) and Pearson's correlation coefficient were determined and were considered statistically significant with r > 0.8 and p < 0.05.

RESULTS AND CONCLUSION

A high correlation was found for both intrarater and interrater reliability based on determination of Pearson's correlation coefficient and the ICC with r > 0.9 and p < 0.001 for all measurements. Based on these results the radiographic measurement of acetabular cup inclination can be considered as a simple measuring tool with high intrarater and interrater reliability. As cup orientation consists of inclination, version and positioning, the exclusive measurement of cup inclination for radiological quality assessment needs to be discussed critically.

摘要

背景与目的

髋臼杯的方向,包括骨盆定位、前倾角和倾斜角,可影响全髋关节置换术(THA)后的短期和长期效果。髋臼杯倾斜角的影像学测量是德国EndoCert认证质量的一项指标。本研究的目的是确定THA后髋臼杯倾斜角影像学测量的观察者内和观察者间可靠性。

材料与方法

在本研究中,四名具有不同专业水平的独立研究者对99例患者的X线片(骨盆前后位X线片)进行了回顾性测量。确定组内相关系数(ICC)和皮尔逊相关系数,当r>0.8且p<0.05时认为具有统计学意义。

结果与结论

基于皮尔逊相关系数和ICC的测定,观察者内和观察者间可靠性均发现高度相关,所有测量的r>0.9且p<0.001。基于这些结果,髋臼杯倾斜角的影像学测量可被视为一种具有高观察者内和观察者间可靠性的简单测量工具。由于髋臼杯方向包括倾斜角、前倾角和定位,对于放射学质量评估仅测量髋臼杯倾斜角需要进行严格讨论。