BACKGROUND

Recognition of nuclear dense fine speckled (DFS) pattern by indirect immunofluorescence (IIF) is not easy. Thus, confirming the presence of these antibodies might be needed. In this study, we aimed to determine the frequency of DFS pattern in our diagnostic laboratory and to investigate the presence of anti-DFS70 antibodies in samples showing DFS pattern by two commercially available research kits retrospectively.

MATERIAL AND METHODS

Seventy-four sequential serum samples with DFS pattern on HEp2010 cell substrates by IIF were included in this study. The semiquantitative DFS70 ELISA Kit (MBL International Corporation, Woburn, UK) was used for detection of anti-DFS70 antibodies in these samples. Twenty selected samples were tested for the presence of anti-DFS70 antibodies using ANA Line Immunoassay (LIA) (Immco Diagnostics, New York, USA).

RESULTS

Sixty-two (83.8%) of 74 serum samples were found positive with ELISA, when 15 U/ml was taken as a reference value. Among 18 samples that were found positive by ELISA, five were negative for anti-DFS70 antibodies by LIA, while 13 were found positive. The lowest ELISA result of the sample that was positive by LIA was found to be 45.3 U/ml. When 45.3 U/ml was considered as a reference value, 45 (60.8%) of 74 serum samples were positive by ELISA. Nineteen of 20 patients had no SARD, while one had systemic lupus erythematosus (SLE).

CONCLUSIONS

DFS pattern should be confirmed with an objective method such as ELISA, LIA, or IB. We think that confirmation tests for detection of anti-DFS70 antibodies should be included in diagnostic algorithms.

摘要

背景

通过间接免疫荧光法(IIF)识别核致密细斑点(DFS)模式并不容易。因此,可能需要确认这些抗体的存在。在本研究中,我们旨在确定我们诊断实验室中DFS模式的频率,并回顾性地通过两种市售研究试剂盒调查显示DFS模式的样本中抗DFS70抗体的存在情况。

材料与方法

本研究纳入了74份通过IIF在HEp2010细胞底物上呈现DFS模式的连续血清样本。使用半定量DFS70 ELISA试剂盒(MBL国际公司,美国马萨诸塞州沃本)检测这些样本中的抗DFS70抗体。使用ANA线性免疫测定法(LIA)(Immco诊断公司,美国纽约)对20份选定样本检测抗DFS70抗体的存在情况。

结果

以15 U/ml作为参考值时,74份血清样本中有62份(83.8%)ELISA检测呈阳性。在ELISA检测呈阳性的18份样本中,5份LIA检测抗DFS70抗体为阴性,而13份呈阳性。LIA检测呈阳性的样本中ELISA最低结果为45.3 U/ml。以45.3 U/ml作为参考值时,74份血清样本中有45份(60.8%)ELISA检测呈阳性。20例患者中有19例无自身免疫性风湿病,1例患有系统性红斑狼疮(SLE)。

结论

DFS模式应通过ELISA、LIA或免疫印迹法(IB)等客观方法进行确认。我们认为抗DFS70抗体检测的确认试验应纳入诊断算法中。