Int Orthop. 2017 Apr;41(4):723-730. doi: 10.1007/s00264-016-3217-0. Epub 2016 May 13.
The aim of the present study was to investigate the long-term outcome and the wear characteristics of two distinct types of ultra-high molecular weight polyethylene (UHMWPE) liners in total hip arthroplasty (THA).
We conducted a retrospective clinical study on patients which were treated with total hip arthroplasty using either Enduron polyethylene (Enduron PE) or Trilogy polyethylene (Trilogy PE) liners based on a minimum of ten year follow up data. Morphological analyses of wear particles from tissue samples, which were harvested during revision surgeries, were also performed.
A total of 79 THAs in the Enduron group and 55 THAs in the Trilogy group were available for analysis. Kaplan-Meier survival with revision for wear-related complications as the endpoint of the Enduron PE liners was lower than that of Trilogy PE liners at ten years (93.5 % and 100 %, P = 0.03). The Enduron group had higher mean linear wear rate than that of the Trilogy group (0.20 ± 0.09 and 0.09 ± 0.03 mm/year, P < 0.01). The incidence of osteolysis for the Enduron group was higher than that of the Trilogy group (33.3 % and 12 %, P = 0.04). Under transmission electron microscopy, the Enduron group had more than 82 % of the particles less than 1.0 μm in size and more than 57 % of the particles less than 0.5 μm.
The long-term performance of Enduron liners was worse than that of Trilogy liners. Further clinical follow-up may be necessary in patients with Enduron PE liners in order to avoid catastrophic complications.
本研究旨在调查全髋关节置换术(THA)中两种不同类型的超高分子量聚乙烯(UHMWPE)衬垫的长期疗效和磨损特性。
我们基于至少十年的随访数据,对使用Enduron聚乙烯(Enduron PE)或Trilogy聚乙烯(Trilogy PE)衬垫进行全髋关节置换术治疗的患者进行了一项回顾性临床研究。还对翻修手术期间采集的组织样本中的磨损颗粒进行了形态学分析。
Enduron组共有79例THA,Trilogy组有55例THA可供分析。以与磨损相关的并发症翻修为终点的Enduron PE衬垫的十年Kaplan-Meier生存率低于Trilogy PE衬垫(93.5%和100%,P = 0.03)。Enduron组的平均线性磨损率高于Trilogy组(0.20±0.09和0.09±0.03 mm/年,P < 0.01)。Enduron组的骨溶解发生率高于Trilogy组(33.3%和12%,P = 0.04)。在透射电子显微镜下,Enduron组超过82%的颗粒尺寸小于1.0μm,超过57%的颗粒尺寸小于0.5μm。
Enduron衬垫的长期性能比Trilogy衬垫差。对于使用Enduron PE衬垫的患者,可能需要进一步的临床随访以避免灾难性并发症。