评估中央孔型有晶状体眼后房型人工晶状体(Hole ICL)植入术后的主观眼内前向散射和视觉质量。

Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation.

机构信息

Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan.

出版信息

Acta Ophthalmol. 2016 Dec;94(8):e716-e720. doi: 10.1111/aos.13092. Epub 2016 Jun 11.

Abstract

PURPOSE

To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation.

METHODS

We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms.

RESULTS

The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017).

CONCLUSIONS

According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one.

摘要

目的

评估具有中央孔(Hole ICL,STAAR Surgical)的后房有晶状体眼人工晶状体植入术后的主观眼内前向散射和视觉质量。

方法

我们前瞻性地检查了 29 例 29 只眼(15 名男性和 14 名女性;年龄 37.2±8.8 岁)接受 Hole ICL 植入术的患者。我们使用散射仪(C-Quant,Oculus)术前和术后 3 个月评估对数 straylight 值[log(s)]的值。患者在术后 3 个月完成了一份详细说明定量分级量表(国家眼科研究所屈光不正生活质量量表-42;NEI RQL-42)症状的问卷。我们比较了术前和术后 log(s)值,并评估了这些值与患者主观症状的相关性。

结果

平均 log(s)值无明显变化,从术前的 1.07±0.20 变为术后的 1.06±0.17(Wilcoxon 符号秩检验,p=0.641)。术前和术后 log(s)值之间存在显著相关性(Spearman 相关系数 r=0.695,p<0.001)。术后 log(s)与问卷中的眩光评分显著相关(Spearman 相关系数 r=-0.575,p=0.017)。

结论

根据我们的经验,Hole ICL 植入术不会引起主观眼内前向散射的显著额外变化。Hole ICL 植入术后眩光症状与术前和术后眼内前向散射显著相关。